<strong>Installation</strong> InstructionsTB/TS/KThermistor Room Temperature SensorsImportant: Retain these <strong>instruction</strong>s1 UnpackingTB/TS/K <strong>Installation</strong>Instructions TG2006072 <strong>Installation</strong>1Dimensions85 (3.35”)- +85 mm (3.35”) 26 mm (1.02”)4 mm (0.16”)2aRequirementsb> 50 cm (20”)c1.5 m(5 ft)d ef gTB/TS/K Thermistor Room Temperature Sensors <strong>Installation</strong> Instructions TG200607 Issue 2, 07/03/2011 1


TB/TS/K<strong>Installation</strong> Instructions2 <strong>Installation</strong> (continued)h2Requirements (continued)ij-10 °C(14 °F)0 °C(32 °F)+50 °C(122 °F)+40 °C measurment(104 °F)0 0 %RH 90 %RHlk 3Remove backplate4Mount backplateabBESA box35 mm (1.38”)35 mm (1.38”)wall box fascia60 mm (2.36”)or wallFRABS35 mm (1.38”)35 mm (1.38”)Remove cutout(s)5 6 Route cablesas required2 TB/TS/K Thermistor Room Temperature Sensors <strong>Installation</strong> Instructions TG200607 Issue 2, 07/03/2011


1 2 3<strong>Installation</strong> InstructionsTB/TS/K2 <strong>Installation</strong> (continued)7Wire to controllerTerminal size 0.5 to 2.5 mm 2(14 to 20 AWG)if IQ5 - 5 4 13 8+ 8 6 *656 A F A = H JK HA1! >1+ 8analogueinputs linked forthermistor (T)5 - 5 4 13! 8 8 6 *656 A F A = H JK HA E ! > "8 8 E "8 analogueinputs linked forthermistor (T)if IQLNote that screened cable is not required forsensor wiring to IQLs. If screened cable is used,the screen must be terminated at the controllerto its supply cable earth.OPTION CONNECT TERMINALSTB/TS 1, 2TB/TS/K 1, 2, 3IQLIQL11+, 13+, 15+, 16, 17OPTIONSTB/TS, TB/TS/KIQL11+/24VAC9 10 11 12 13COMC1 2 3IQL11+/2301 2 3COMC15 16 17 18 193 1 22 1 3/K TB/TSTB/TS /KIQL13+, 15+, 161 2 3 4 5COM COM C21 22 23 24 25 26 27 28IQL171 2 3 4 5COM AI 10V C0V21 22 23 24 25 26 27 282 1 3TB/TS /K2 1 3TB/TS /KTB/TS/K Thermistor Room Temperature Sensors <strong>Installation</strong> Instructions TG200607 Issue 2, 07/03/2011 3


TB/TS/K<strong>Installation</strong> Instructions<strong>Installation</strong> (continued)8Assemble unit‘click’9Set up IQ Sensor typesIf IQ controllerIt is recommended to use SET (software tool) for the setting of sensor type modules. For allIQ2 series controllers with firmware version 2.1 or greater, or IQ3 series controllers, select theappropriate SET Unique Sensor Reference from the following:Knob: Knob TB 3 deg trim (guaranteed ±3 trim)alternatively: Knob T 3 deg trim (±3 ±20% linear)Thermistor: Thermistor TBTS (°C)Thermistor TBTS F (°F)(change the values of U and L to those in the following table)Alternatively, set scaling mode to 5 (characters) and enter scaling manually, as defined in thetables below.Note that for IQ3 the scaling mode and exponent (E) do not need to be set up.For all other IQ controllers see Sensor Scaling Reference Card TB100521AThermistor(0 to +40 °C)Units °C °FY Input type 1 (thermistor volts)E Exponent 3U Upper 50 122L Lower -5 23P Points 6x Ix Ox (°C) Ox (°F)1 2.641 50 1222 3.47 40 1043 4.46 30 864 6.663 10 505 7.668 0 326 8.102 -5 23Knob(trim -3 to +3)Y Input type 3 (Thermistor Kohms)E Exponent 1U Upper 3.2L Lower -3.2P Points 4x Ix Ox1 .95 -3.12 1.05 -33 8.95 +34 13.05 +3.110Test system/K3 DisposalIf IQ13If IQL∆ T∆ SPIQL Strategy <strong>Installation</strong>InstructionsWEEE Directive :At the end of their useful life the packagingand product should be disposed of by asuitable recycling centre.Do not dispose of with normal householdwaste. Do not burn.Please send any comments about this or any other <strong>Trend</strong> technical publication to techpubs@trendcontrols.com© 2011 Honeywell Technologies Sàrl, ECC Division. All rights reserved. Manufactured for and on behalf of the Environmental and Combustion Controls Divisionof Honeywell Technologies Sàrl, Ecublens, Z.A. La Pièce, 16, 1180 Rolle, Switzerland by its Authorized Representative, <strong>Trend</strong> Control Systems Limited.<strong>Trend</strong> Control Systems Limited reserves the right to revise this publication from time to time and make changes to the content hereof without obligationto notify any person of such revisions or changes.<strong>Trend</strong> Control Systems LimitedAlbery House, Springfield Road, Horsham, West Sussex, RH12 2PQ, UK. Tel:+44 (0)1403 211888 Fax:+44 (0)1403 241608 www.trendcontrols.com<strong>Trend</strong> Control System USA6670 185 th Avenue NE, Redmond, Washington 98052, USA. Tel:(425) 869-3900 Fax:(425) 869-8445 www.trendcontrols.com4 TB/TS/K Thermistor Room Temperature Sensors <strong>Installation</strong> Instructions TG200607 Issue 2, 07/03/2011

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!