13.07.2015 Views

SIPROTEC 4 7SJ63 Multifunction Protection Relay - Siemens

SIPROTEC 4 7SJ63 Multifunction Protection Relay - Siemens

SIPROTEC 4 7SJ63 Multifunction Protection Relay - Siemens

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

5 Overcurrent <strong>Protection</strong> / <strong>7SJ63</strong>Application5The <strong>SIPROTEC</strong> 4 <strong>7SJ63</strong> unit is a numericalprotection relay that also performs controland monitoring functions and therefore supportsthe user in cost-effective power systemmanagement, and ensures reliable supply ofelectric power to the customers. Local operationhas been designed according to ergonomiccriteria. A large, easy-to-read graphicdisplay was a major design aim.ControlThe integrated control function permits controlof disconnect devices (electrically operated/motorizedswitches) or circuit-breakersvia the integrated operator panel, binary inputs,DIGSI 4 or the control and protectionsystem (e.g. SICAM). The present status (orposition) of the primary equipment can bedisplayed. <strong>7SJ63</strong> supports substations withsingle and duplicate busbars. The number ofelements that can be controlled (usually 1 to5) is only restricted by the number of inputsand outputs available. A full range of commandprocessing functions is provided.Programmable logicThe integrated logic characteristics (CFC)allow the user to implement their own functionsfor automation of switchgear (interlocking)or a substation via a graphic userinterface. The user can also generate userdefinedmessages.5/118Line protectionThe <strong>7SJ63</strong> units can be used for line protectionof high and medium-voltage networkswith earthed (grounded), low-resistanceearthed, isolated or compensated neutralpoint.Motor protectionWhen protecting motors, the <strong>7SJ63</strong> relays aresuitable for asynchronous machines of allsizes.Transformer protectionThe <strong>7SJ63</strong> units perform all functions ofbackup protection supplementary to transformerdifferential protection. The inrushsuppression effectively prevents tripping byinrush currents.The high-impedance restricted earth-faultprotection detects short-circuits and insulationfaults on the transformer.Backup protectionThe relays can be used universally for backupprotection.Metering valuesExtensive measured values, limit values andmetering values permit improved systemsmanagement.Fig. 5/105 Function diagram<strong>Siemens</strong> SIP · 2006

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!