13.07.2015 Views

SIPROTEC 4 7SJ63 Multifunction Protection Relay - Siemens

SIPROTEC 4 7SJ63 Multifunction Protection Relay - Siemens

SIPROTEC 4 7SJ63 Multifunction Protection Relay - Siemens

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

5 Overcurrent <strong>Protection</strong> / <strong>7SJ63</strong>Technical dataRS485ConnectionFor flush-mounting housing/surface-mounting housing withdetached operator panelFor surface-mounting housingwith two-tier terminal on thetop/bottom partDistanceTest voltageFiber opticConnection fiber-optic cableFor flush-mounting housing/surface-mounting housing withdetached operator panelFor surface-mounting housingwith two-tier terminal on thetop/bottom partOptical wavelengthPermissible path attenuationDistanceMODBUS RTU, ASCII, DNP 3.0Isolated interface for data transferto a control centerTransmission rateRS485ConnectionFor flush-mounting housing/surface-mounting housing withdetached operator panelFor surface-mounting housingwith two-tier terminal at thetop/bottom partDistanceTest voltageFiber-opticConnection fiber-optic cableFor flush-mounting housing/surface-mounting housing withdetached operator panelFor surface-mounting housingwith two-tier terminal at thetop/bottom partOptical wavelength9-pin subminiature connector,mounting location “B”At the bottom part of the housing:shielded data cable1000 m/3300 ft ≤ 93.75 kbaud;500 m/1500 ft ≤ 187.5 kbaud;200 m/600 ft ≤ 1.5 Mbaud100 m/300 ft ≤ 12 Mbaud500VACagainstearthIntegr. ST connector for FO connection,mounting location “B”At the bottom part of the housingImportant: Please refer to footnotes1) and 2) on page 5/148820 nmMax. 8 dB, for glass fiber 62.5/125 µm500 kB/s 1.6 km/0.99 miles1500 kB/s 530 m/0.33 milesPort BUp to 19200 baud9-pin subminiature connector,mounting location “B”At bottom part of the housing:shielded data cableMax. 1 km/3300 ft max. 32 unitsrecommended500 V AC against earthIntegrated ST connector for fiber-opticconnectionMounting location “B”At the bottom part of the housingImportant: Please refer to footnotes1) and 2) on page 5/148820 nmPermissible path attenuation Max 8 dB. for glass fiber 62.5/125 µmDistanceMax. 1.5 km/0.9 milesTime synchronization DCF77/IRIG-B signal (Format IRIG-B000)Connection9-pin subminiature connector(SUB-D)(terminal with surface-mountinghousing)Voltagelevels5V,12Vor24V(optional)FunctionsDefinite-time overcurrent protection, directional/non-directional(ANSI 50, 50N, 67, 67N)Operating mode non-directionalphase protection (ANSI 50)Setting rangesPickup phase elementsPickup earth elements3-phase (standard) or 2-phase(L1 and L3)I>, I>> 0.5 to 175 A or ∞ 1) (in steps of 0.01 A)I E>, I E>> 0.25 to 175 A or ∞ 1) (in steps of 0.01 A)Delay times T0to60sor∞ (in steps of 0.01 s)Dropout delay time T DO 0to60s(instepsof0.01s)TimesPickup times (without inrushrestraint, with inrush restraint+10ms)With twice the setting valueWith five times the setting valueDropout timesNon-directionalApprox. 30 msApprox. 20 msApprox. 40 msDirectional45 ms40 msDropout ratio Approx. 0.95 for I/I nom ≥ 0.3TolerancesPickupDelay times T, T DO2%ofsettingvalueor50mA 1)1%or10msInverse-time overcurrent protection, directional/non-directional(ANSI 51, 51N, 67, 67N)Operating mode non-directionalphase protection (ANSI 51)Setting rangesPickup phase element I PPickup earth element I EPTime multiplier T(IEC characteristics)Time multiplier D(ANSI characteristics)Trip characteristicsIECANSIUser-defined characteristicDropout settingWithout disk emulationWith disk emulationTolerancesPickup/dropout thresholds I p, I EpPickup time for 2 ≤ I/I p ≤ 20Dropout ratio for 0.05 ≤ I/I p≤ 0.93-phase (standard) or 2-phase(L1 and L3)0.5to20Aor∞ 1) (in steps of 0.01 A)0.25 to 20 A or ∞ 1) (in steps of 0.01 A)0.05 to 3.2 s or ∞ (in steps of 0.01 s)0.05 to 15 s or ∞ (in steps of 0.01 s)Normal inverse, very inverse,extremely inverse, long inverseInverse, short inverse, long inversemoderately inverse, very inverse,extremely inverse, definite inverseDefined by a maximum of 20 valuepairs of current and time delayApprox. 1.05 · setting value I p forI p/I nom ≥ 0.3, corresponds to approx.0.95 · pickup thresholdApprox. 0.90 · setting value I p2%ofsettingvalueor50mA 1)5 % of reference (calculated) value+ 2 % current tolerance, respectively30 ms5 % of reference (calculated) value+ 2 % current tolerance, respectively30 ms51) At I nom = 1 A, all limits divided by 5.<strong>Siemens</strong> SIP · 20065/137

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!