Fn_10:START / STOP ControlThis parameter is used to decide if the Start and Stop function will be controlled by the Keypad orby Remote Operation (TM2).0: Keypad Control1: Remote Operation (TM2)Note:The STOP Key on the Keypad can still be used for Emergency Stopping even if the START /STOP Control is from TM2 (Fn_10 = 1). (Refer to Fn_48)Fn_11:Frequency Command Selection0: Run by Fn_25 Master Reference1: Run by Frequency Setting Potentiometer on Keypad2: Run by Speed Pot on TM2 or Remote Signal (Terminals (12 / 13 / 14))3: Run by Multi-Function Input Frequency Command (Terminals 6 / 7 / 8))TM2123JP1TM2123JP1TM2123JP1TM2123JP112 13 14 15FM- FM+12 13 14 15FM- FM+12 13 14 15FM- FM+12 13 14 15FM- FM+FCW WIPER FCCW+ -+ -+ -0 - 10VDC Speed Ref. 0 - 5VDC Remote 4 - 20mA Signal 0 - 10VDC Remote(Fn_11) to 2(Fn_11) to 2(Fn_11) to 2(Fn_11) to 2Use a (10K, 2 Watt)For a Remote 5VDCFor a RemoteFor a RemotePot with the wiper inSignal, Jumper (JP1)4 - 20mA Signal,0 - 10VDC Signal,Terminal 13. JumperPins 1 & 2.Jumper (JP1)Jumper (JP2)(JP1) Pins 1 & 2.Pins 2 & 3.Pins 2 & 3.28