Tab.3(*) as soon as availableAPPLICABLEACCESSORIES BOARDSWING 2SLIDENEWMETEX ROLLING MINIGATE1 24VGATE 1 GATE 2 GATE 124VGATE224VGATE224VPLUSUSER224VFoto 50 √ √ √ √ √ √ √ √ √ √ √Foto 60 √ √ √ √ √ √ √ √ √ √ √Ghost 40 √ √ √ √ √ √ √ √ √ √ √Ghost 40 Bus * * * * *Ghost 50 √ √ √ √ √ √ √ √ √ √ √Fotobat √ √ √ √ √ √ √ √ √ √ √SLIM √ √ √ √ √ √ √ √ √ √ √Heater √ √ √ √ √ √ √ √ √ √ √GSM radio transmitter √ √ √ √ √ √ √ √ √ √ √Radiodec Prox √ √ √ √ √ √ √ √ √ √ √Kit Antenna √ √ on Rxplug inon Rxplug inon Rxplug in√ √ on Rxplug in√√230V warning lamp(Flash, Lamp…)√ √ √ √ √Warning lamp with flashcard √ √ √Flash 24V √ √ √ √ √Security edge √ √ √ √ √ √ √ √Key switch √ √ √ √ √ √ √ √ √ √ √Pushbutton boards √ √ √ √ √ √ √ √ √ √ √Palm √ √ √Administration cardmagnetic loop√ √ √ √ √ √ √ √ √ √ √Backup battery √ √ √ √ √ √ √ √ √ √ √Additional power supplier √ √ √ √ √ √ √ √ √ √ √Signal plug in receiver √ √ √ √Electric lock √ √ √ √ √Battery recharge card √ √Optional display module√Modulo RF √ √ √ √ √ √RF module √ √ √Tab.4PARAMETERS ADJUSTBLEWITH TRIMMERSWING 2SLIDENEWMETEX ROLLING MINIGATE1 24VGATE 1 GATE 2 GATE 124VGATE224VGATE224VPLUSUSER224VTime of pause adjustment √ √ √ √ √ √ √ in progr. tab.7 √ tab.7Motor torque adjustment √ √ √ √ √Leaf delay adjustment √ in progr. in progr. √ withdisplayWorking time adjustment √ √ √Slow down time adjustment √ √ √ √ withdisplayAnti-crushing sensibility √ √ palm palm √ √ √Brake adjustment √ √Courtesy light switch onadjustment√Motors speed adjustment √ √ √ tab. 7Legend:With display= optionalPalm= with Palm accessoryIn prog. = programming phase67
Tab.5FUNCTIONING LOGIC SWING 2 SLIDENEWMETEX ROLLING MINIGATE1 24VGATE 1 GATE 2 GATE 124VGATE224VGATE224VPLUSUSER224VAutomatic √ √ √ √ √ √ √Automatic√Semiautomatic √ √ √ √Dead man√Of security √ √Semiautomatic of security√Automatic 1 √ √Automatic 2 √ √Manual √ √ √ √Step-by-step√Step-by-step Type 1Step-by-step Type 2√√Condominium √ √Automatic of security √ √Tab.6PROGRAMMING MODALITIES SWING 2 SLIDENEWMETEX ROLLING MINIGATE1 24VGATE 1 GATE 2 GATE 124VGATE224VGATE224VPLUSUSER224VSelf-learning with limit switch √ √ √ √ √ √Self-learning without limitswitchManual time adjustment bytrimmer√ √ √ √ √ √√ √ √Tab.7PUSHBUTTONS ON BOARD SWING 2 SLIDENEWMETEX ROLLING MINIGATE1 24VGATE 1 GATE 2 GATE 124VGATE224VGATE224VPLUSUSER224VSelf-learning √ √ √ √ √ √ √Radio transmitter self-learning √ √ √ √Manuel opening push buttonManuel closing push button√√Start push button √ √Motors speedWorking logicPedestrian openingRadio transmitter memoryindicator√√√√Pausing time adjustment √ √Automatic or automatic 2:AutomaticSemiautomatic:Dead man:Security, autom. of security:Automatic 1Step-by-step Type 1:Manuel:Step-by-step:Step-by-step Type 2:Condominium68One start impulse opens, one start impulse in opening is refused, one start impulse during pause closes all at once otherwisecloses again in automatic at the end of the pause, a start impulse in closing inverts.a start impulse opens, a start impulse in opening is refused, a start impulse in pause closes all at once, one start impulse inclosing stops the movement, a second impulse in closing invertsa start impulse opens, at the end of the opening cycle a start impulse is necessary to close again, a start impulse in openingstops the movement a successive one inverts the movement, one in closing inverts the movementHold start opens, pedestrian start hold closes, at the push button release the automation stopsA start impulse opens, a start impulse in both opening and closing invertsA start impulse opens, at the end of the opening cycle a start impulse is necessary to close again, a start impulse in bothopening and closing inverts the movement.A start impulse opens, a start in opening is not accepted, one in pause is not accepted, one in closing invertsthe movementThe repeated start impulse realises the sequence open, stop, close, stop, open, stop close….A start impulse opens, a start impulse closesA start impulse opens, a start impulse during slow down, pause or stop on obstacle, stops the movement. A start impulse isnecessary to close again. In closing a start impulse stops, the second one invertsThe repeated start realizes the sequence open, stop, close, open, stop, close…= for all door and gate types shutters = for overhead doors and rolling