13.07.2015 Views

Final Report on Torque with Cross Force Comparison No. MT01 ...

Final Report on Torque with Cross Force Comparison No. MT01 ...

Final Report on Torque with Cross Force Comparison No. MT01 ...

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<str<strong>on</strong>g>Final</str<strong>on</strong>g> <str<strong>on</strong>g>Report</str<strong>on</strong>g> of <strong>MT01</strong>9. Discussi<strong>on</strong> and c<strong>on</strong>clusi<strong>on</strong>Sixteen calibrati<strong>on</strong> laboratories in Thailand participated into this interlaboratorycomparis<strong>on</strong> of torque <strong>with</strong> cross force from 40 N·m to 400 N·m clockwise andanticlockwise directi<strong>on</strong>. High accuracy torque transfer wrench was circulated as theartifact for the whole comparis<strong>on</strong>. In order to ensure the reliability of the artifact, theartifact was tuned back to pilot laboratory to m<strong>on</strong>itoring the stability every week duringthe comparis<strong>on</strong> was being d<strong>on</strong>e. From the m<strong>on</strong>itoring results, the behaviors of the artifactduring the comparis<strong>on</strong> period were well characterized and it was c<strong>on</strong>firmed that thecapabilities of artifact to achieve this comparis<strong>on</strong> were sufficient.<strong>No</strong>t <strong>on</strong>ly comparis<strong>on</strong> process but also observati<strong>on</strong> of creep of the loader and effectof varied cross force was required as the metrology investigati<strong>on</strong>. The observati<strong>on</strong>s wereuseful to understand their behavior. From this knowledge, it is possible to reas<strong>on</strong>ablyestimate the uncertainty due to creep of the loader and varied cross force effect.Participant’s technical competences were determined and were expressedquantitatively by two terms, deviati<strong>on</strong> from the reference values and E n numbers. Thecalibrati<strong>on</strong> capability in the range 40 N·m to 400 N·m clockwise and anticlockwisedirecti<strong>on</strong> of sixteen participating laboratories were generally found acceptability <strong>with</strong>intheir claimed uncertainties. The results of this comparis<strong>on</strong> were satisfactory.33

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!