D. Estimate Pressure Available at “Worst-Case” Head18 Pressure change due to elevation change from the POC to thehighest head in the system. 10 ft. x 0.433 = 4.33 PSI19 Pressure subtotal (subtract Line 18 from Line 17; for worst caseheads which are lower than the POC, add Lines 17 and 18) 48.66 PSI20 Estimated Pressure Available at worst case-headtwo-thirds of subtotal: Line 19 48.66 PSI x 0.67 = 32.60 PSIPressure Available for Sprinkler Selection and Operation32.60 PSI