13.07.2015 Views

GE Fanuc | Series 90-30 | IC693PRG300 - GE Fanuc PLC

GE Fanuc | Series 90-30 | IC693PRG300 - GE Fanuc PLC

GE Fanuc | Series 90-30 | IC693PRG300 - GE Fanuc PLC

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

4Table 4-1. Micro <strong>PLC</strong> Parameters (continued)Parameter Description Possible Values Default ValueIn RefAddr Discrete input reference %I00001 not editable %I00001Input Size Discrete input size 8 not editable 8Out RefAddr Discrete output reference %Q00001 %Q00001Output Size Discrete output size 6 6The HHP is used to develop, debug, and monitor ladder logic programs, and to monitordata tables. You can use the HHP to perform the following tasks:Statement List logic program development, including insert, edit, and deletefunctions. The Statement List programming instructions provide basic (boolean)instructions to execute logical operations such as AND and OR, and many functionsto execute advanced operations including arithmetic operations, data conversion,and data transfer.On-line program changesHHP Configuration ScreensSearch logic programs for instructions and/or specific referencesMonitor reference data while viewing logic programMonitor reference data in table form in binary, hexadecimal, or decimal formatsMonitor timer and counter valuesView <strong>PLC</strong> scan time, firmware revision code and current logic memory useLoad, store, and verify program logic and configuration between the Hand-HeldProgrammer and a removable Memory Card (IC693ACC<strong>30</strong>3) which allows programsto be moved between <strong>PLC</strong>s or loaded into multiple <strong>PLC</strong>sStart or stop the <strong>PLC</strong> from any mode of operationNoteUnlike other <strong>Series</strong> <strong>90</strong>-<strong>30</strong>/20 models, the <strong>Series</strong> <strong>90</strong> Micro <strong>PLC</strong> requiresthat, after a program has been edited, you save the program to the userprogram in non-volatile flash memory. Refer to Storing the User ProgramUsing the HHP on page 4-6 for the required procedure for savingprograms when a Micro <strong>PLC</strong> program is modified in any way (create,edit, insert, etc.).1. The following screen (Main Menu) will be displayed on the Hand-Held Programmerafter the <strong>Series</strong> <strong>90</strong> Micro <strong>PLC</strong> has successfully completed its power-up sequence._ 1. PROGRAM

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!