1Table 1-6. Range and Size of User References for the <strong>Series</strong> <strong>90</strong> Micro <strong>PLC</strong>Reference Type Reference Range SizeUser program logic Not applicable 1K wordsDiscrete inputs %I001 - %I016 16 bitsDiscrete inputs, internal %I017 - %I048 32 bitsDiscrete outputs %Q0001 - %Q0016 12 bitsDiscrete outputs, internal with LED indicators %Q013 - %Q016 4 bitsDiscrete outputs, internal %Q017 - %Q048 32 bitsDiscrete globals %G0001 - %G1280 1280 bitsDiscrete internal coils %M0001 - %M1024 1024 bitsDiscrete temporary coils %T0001 - %T0256 256 bitsSystem status references %S0001 - %S0032 32 bits%SA001 - %SA03232 bits%SB001 - %SB03232 bits%SC001 - %SC03232 bitsSystem register references %R0001 - %R0256 256 wordsAnalog and High Speed Counter inputs %AI001-%AI016 16 wordsAnalog outputs %AQ001 - %AQ016 16 wordsSystem registers %SR001 - %SR016 16 wordsFor reference table viewing only; can not be referenced in a user logic program.Using the Hand-Held ProgrammerWhen power is applied to the <strong>PLC</strong>, the Hand-Held Programmer begins diagnostic testson its hardware. Once these tests are successfully completed, the Hand-HeldProgrammer can interact with the <strong>PLC</strong>.Initially, you must select an operating mode: program mode, protection mode, datamode, or configuration mode. When setting up a new system, you will normally wantto select configuration mode first, in order to configure the I/O modules to be used in thesystem. In configuration mode, you can identify which <strong>PLC</strong> backplane slots contain I/Omodules, and the size (number of Input or Output points) for each module. Based onthe size of each module, a range of discrete input and output references can either beassigned automatically by the Hand-Held Programmer, or optionally specified by theuser. The configuration of these I/O modules can be changed at any time.After configuring the I/O modules, the next step is to program the actual logicprogram. Program mode is selected for this. Once in program mode, you can create,modify, and monitor the execution of program logic instructions. The optional <strong>Series</strong><strong>90</strong> Memory Card or EEPROM can be used at any point to save or recall a particularversion of the program.While attempting to debug a logic program, you may need to view and modify data inone or more reference tables. Selecting data mode allows you to accomplish this. Oncein data mode, you can view any of the <strong>PLC</strong> reference tables in binary, hexadecimal, orsigned decimal format. Only the system register (%R) table can be viewed intimer/counter format.GFK-0402GChapter 1 Introduction to the Hand-Held Programmer1-7

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!