COMMISSIONING1.1 To commission:COMMISSIONING—Replace the baffle and log guard.—Check the door alignment and catch operation andadjust if required (see Maintenance & Servicing,Section 7).—Check the soundness of door seals, castings and joints.—Check the operation of the air controls.1.2 Now carry out a final smoke draw test:—Warm the flue with a blowlamp, or similar, for about 10minutes.—Place a smoke pellet on the centre of the grate, with theair controls open.—Close the door. Smoke should now be drawn up the flueand be seen to exit from the flue terminal.—Explain the cleaning and routine maintenancerequirements.—Explain the requirement to use a suitable fireguardwhen children, elderly or infirm persons are near theappliance.—Record retailer/supplier and installer details inAppliance Commissioning Checklist (page 3,Instructions for Use).—Record serial number in Appliance CommissioningChecklist (page 3, Instructions for Use).This number is required when ordering spare parts andmaking warranty claims (see diagram below).Product:Model No:Serial No:—Complete test with all doors and windows closed in theroom where the appliance is fitted.—If there are any extractor fans in adjacent rooms the testmust be repeated with the fans running on maximumand with interconnecting doors open.PR8828—Check the effect of ceiling fans during the test.If the test fails, re-check the suitability of the flue systemand ventilation. An inadequate air supply to the room ispotentially dangerous.—Give this instruction manual to the customer.—Light the appliance and slowly increase the temperature.—Ensure no combustion products enter the room.—Open the main fire door when the appliance reachesoperating temperature and carry out a spillage test with asmoke match or pellet around the door opening.1.3 If excessive spillage occurs allow the appliance to cool andre-check the flue system and ventilation.1.4 Finally:—Explain to the user the safe operation of theappliance, use of the controls and the importance ofonly using suitable fuels.—All open flued appliances can be affectedby temporary atmospheric conditions which mayallow fumes to enter the house. Because of thisit is recommended that an electronic carbonmonoxide detector conforming to BSEN50291 be fittedand maintained.24

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!