ENERGY TOP W> > > Heating division> SPECIFICATIONSFLUE GAS EVACUATIONVarious solutions are available for the air intake and flue gas evacuation on the ENERGY TOP W wall-hung boilers, for either individual andmodular installation. The low flue gas temperature implies special polypropylene accessories can be used. As regards individual dischargesystem, both 80 mm separate and 80/125 mm coaxial flue gas outlet configurations are available, with comburent air intake either from theroom or the outside. All basic accessories close to boiler’s stack are fitted with test fittings for combustion analysis.> INDIVIDUAL EVACUATION SYSTEM > TECHNICAL DATAcode 041000X090° PPs bend, Ø 80 mm,with flue test pointcode 1KWMA70WPPs vertical connection, Ø80 mm, with flue test pointcode 041007X080/125 coaxial adapter, with fluetest pointENERGY TOP W 80 W 125StackMaximum stack pressure head at Pmax pascal 200 250Maximum length 80/125 m 4 2Maximum separate length meq 20 10As regards the modular installations, flue gas manifolds are available for total output of around 500 kW.If these ducts are used, combustion air intake occurs directly from the boiler room, through the air intake grills included in the kit.8 9 9 9 9 10118code 041026X0Condensate drain trap complete with fasteningbrackets10code 041019X01 mt PPs extension, ø 200 mm MF> POSSIBLE MODULAR CONFIGURATIONSINPUTkWTOT. OUTPUT (kW) MODULES QTY TOP W DIMENSIONSW x D x H80/60°C 50/30°C 1 2 3 4 mmFLUESMANIFOLDDIAMETER75 73,5 79,5 80 - - - 820x450x2240 -116 113,7 123,0 125 - - - 820x450x2240 -150 147,0 159,0 80 80 - - 1325x450x2240191 187,2 202,5 125 80 - - 1325x450x2240225 220,5 238,5 80 80 80 - 1830x450x2240 200 mm232 227,4 246,0 125 125 - - 1325x450x2240266 260,7 282,0 125 80 80 - 1830x450x22409code 041028X0Grey PPs flue gas manifold kit (L=600mm - ø200 mm) for “side-by-side” modular installation,complete with clapet valves, vertical connections,gaskets and bracketsINPUTkW11code 041016X090° PPs bend, ø 200 mm MFTOT. OUTPUT (kW) MODULES QTY TOP W DIMENSIONSW x D x H80/60°C 50/30°C 1 2 3 4 mm300 294,0 318,0 80 80 80 80 2335x450x2240307 300,9 325,5 125 125 80 - 1830x450x2240341 334,2 361,5 125 80 80 80 2335x450x2240348 341,1 369,0 125 125 125 - 1830x450x2240382 374,4 405,0 125 125 80 80 2335x450x2240423 414,6 448,5 125 125 125 80 2335x450x2240464 454,8 492,0 125 125 125 125 2335x450x2240FLUESMANIFOLDDIAMETER200 mm10
ENERGY TOP W> > > Heating division> SPECIFICATIONSSETTING AND CONTROLThe ENERGY TOP W series boilers boast an evolved electronics that can manage as standard up to two direct heating zones or an eventual storagecylinder with one direct zone, without requiring additional electronic controllers.PS: Diagrams are for mere example only and need to be verified according to the specific installation.> MIXED CIRCUIT WITH PRIORITY TO THE STORAGE TANKLegionella disinfection signalRecirculationtimerEach boiler or cascade of boilerscan be connected to an outdoortemperature probe for flowtemperature compensationoperation. MASTER-SLAVEinterconnection between the boilerspermits multiple cascadeconfigurations without requiringadditional control boards.> MIXED CIRCUIT WITH PRIORITY OR SIMULTANEOUS OPERATION OF THE STORAGE TANKLegionella disinfection signalRecirculationtimerThe Legionella protection function,after a programmable time interval,ensures the temperature inside thestorage cylinder remains at 65°Cfor 15 minutes. When Legionellaprotection is active, the boiler’selectronics sends an output signal(voltage-free contact) that can beused to control a recirculating pump.This ensures the entire water contentin the circuit is protected.In the case of combined systems (without diverting valve) domestic hot water storage cylinder can be heated simultaneously with the centralheating or as a priority function depending on the characteristics of the system.11