13.07.2015 Views

Rexnord-Stephan S4 Catalogue

Rexnord-Stephan S4 Catalogue

Rexnord-Stephan S4 Catalogue

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

04-2007 3P0200-XX7. Technical AppendixDiagrams77.3.16 Spring-applied single-disk safety brake for direct current and dry runIn the electromagnetic single-disk brake, the braking force is applied through springs and the brake is electricallyreleased. In case of a power failure, the brake is applied. This allows it to meet the predetermined safety requirements.The brakes can be supplied with a manual release upon request.The brakes are manufactured and tested according to VDE 0580 and correspond to CENELEC Memorandum no.3, part 3, par. 2.3 of the EC safety directives.Standard voltages:102 VDC / 230 VAC for motor output up to 3 kW178 VDC / 400 VAC for motor output starting at 4 kWOther voltages can be supplied and must be specified when ordering.Technical data:The response times apply to normal operating temperatures and rated voltage with adjusted gap. The valueslisted are subject to the regular tolerances.t 1 (operating time) is the time from switching on the voltage to the drop-off of the brake torque to 10% of the ratedtorque T B .t 2 or t 3 (breaktime) is the time from switching off the voltage to an increase of the brake torque to 90% of its ratedvalue. t 2 applies to switching on the DC side, t 3 to switching on the AC side.The brakes correspond to enclosure type IP55 and, therefore are protected against damaging dust accumulationsand jet water.T29