04-2007 3P0200-XX7. Technical Appendix7.3.19 Power capability per brakingIn general, the permissible operating frequency of a brake motor is limited by the heating of the motor. The brakeoutput should be determined for each braking W for control purposes.W = 0.0055 x n 1 2 x (J zus + JE)The permissible value W Rmax can be found in the diagram.T32