04-2007 3P0200-XX7. Technical AppendixPermissible rated external loads F rN (N) at the output shaft for multi-stage gear units with elongatedbearing casing (SI4 only)Version SICL - SIFL - SICP - SIFP for SI4n 2 F rN Sizemin -1 (N) 46B 46C 56B 56CF rc 32500 19000 54500 22900≤ 60 F rm 15000 8900 26500 11000F re 9900 5800 17500 7200F rc 32500 19000 54500 2290075 F rm 15000 8900 26500 11000F re 9900 5800 17500 7200F rc 28000 15500 54500 2290095 F rm 13500 6500 26500 11000F re 9000 5000 17500 7200F rc 26000 - 48000 -150 F rm 13500 - 25000 -F re 9000 - 16000 -F rc 26000 - 48000 -240 F rm 13500 - 25000 -F re 9000 - 16000 -F rc = FrN x A rcF rm = FrN x A rmF re = FrN x A re7.4.12 Installation, General ConditionsThe drive units must be installed or attached free of vibration or mounted on a flat, rigid and solid frame or foundationin order to avoid vibrations.CAUTION!The drive units must be aligned with utmost care! Stress and strain in the housing must be avoided.To align the gear unit, place it on 3 of the 4 mounting points and use shims to match the fourth point to an accuracyof less than 0.2 mm.T52