04-2007 3P0200-XX8. Starting up8 Starting up8.1 ChecksllllllThe specified position-dependent oil level must be checked prior to start-up.The oil inspection and drain plugs as well as the breather screws and valves must be freely accessible.Check direction of rotation, especially in connection with backstops.Check all fastening elements.The check must be performed with the drive unit in the original mounting position.Screw plugs must be replaced by the supplied breather valves in the position-dependent positions inaccordance with the section on "Positions of Lubricant Attachments".8.2 MotorObserve the motor operating instructions!8.2.1 Electrical connectionl The cable type and cross sections must comply with regulations.l The rated power and the connection method are specified on the motor ratings plate. A circuit diagram isprovided in the motor terminal box.l Installation must be performed in compliance with EN 60079-14.8.2.2 Cable entryllllllAll cable entry fittings must be firmly secured.Power supply cables must be connected to the terminal box and secured with a nut and spring lock washer.The wiring must be connected by a qualified electrician.Grounding of the electrical system must comply with applicable safety regulations.With regard to motor protection, reference is made to the applicable regulations in accordance withDIN EN 60034 or IEC 34, VDE 0105 or IEC 364.Particular care must be taken when closing the terminal box to ensure that the seal is fitted correctly. Screwedcable glands that are not required must be securely closed off.8T67

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!