13.07.2015 Views

Ascot Owner's Manual - Pine Tree Stove Shoppe

Ascot Owner's Manual - Pine Tree Stove Shoppe

Ascot Owner's Manual - Pine Tree Stove Shoppe

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Initial InstallationVENT RESTRICTOR SETTING:To access restrictor plate, look at the left hand rear corner of the unit. There is a small rectangular holein the air jacket. Loosen the 1⁄4” hex head bolt and adjust to the correct setting. Slide the hex bolt to thenext setting and retighten the bolt to ensure the plate does not move15’ (4.57m) 10’ (3.05m)523415234Figure 19. Vent Restrictor Settings.1 Refer to Figure 20 to determine were the vent restrictor should beset for proper operation.The numbers in the chart represent the actual vent restrictorsettings. Although the numbers do not appear on the unit use thisguide to follow.Ensure that the setscrew is retightened and the unit is checked forproper operation.5’ (1.52m)2’ (0.62m) 2’ (0.62m)18”(0.46m)54321Vent Restrictor SettingsFigure 20. Possible Vent Configurations.Wait for the unit to warm up to operating temperature to ensure a proper and clean burning unit.NOTE: The total length of the vent pipes can not exceed 15 feet (4.6 m). Any combination of rise andrun can be used as long as it lays within the shaded area.18