Px4x Series40 Series protection devices provide a wide range ofprotection and control functions and meets therequirements of a wide market segment.The preferred applications are:• P14x: Feeder management relay suitable for MV andHV systems• P24x: Rotating Machine Management relay forapplication on a wide range of synchronous andinduction machines• P34x: Generator protection for small to sophisticatedgenerator systems and interconnection protection• P44x: Full scheme Distance protection relays for MV,HV and EHV systems.• P54x: Line Differential protection relays for HV/EHVsystems with multiple communication options as wellphase comparison protection for use with PLC.• P74x: Numerical Busbar protection suitable forapplication on MV, HV and EHV busbars• P94x: Frequency protection for load shedding, loadrestoration and generator abnormal detectionCONTROL> Programmable scheme logicSimple logic equations as well as block logic is availablein a number of 20 series relays, see figure 1.Powerful graphical logic available in the 30 and 40 seriesrelays allows the user to customize the protection andcontrol functions of the relay. It is also used to programthe functionality of the opto-isolated inputs, relay outputs,LED and user alarms.The Programmable Scheme Logic can be used toimplement additional supervision features, such as tripcircuit supervision or implement complex logic such asfrequency restoration schemes. Schemes have beendeveloped capable of supervising the trip coil and circuitwith the circuit breaker open or closed.The Px40 gate logic includes OR, AND, NOT andmajority gate functions, with the ability to invert the inputsand outputs, and provide feedback. A number of generalpurpose logic timers are also available as well as thosetimers used to condition the relay contacts. The system isoptimized (event driven) to ensure that the protection outputsare not delayed by the PSL operation.The Programmable Scheme Logic is configured using thegraphical <strong>MiCOM</strong> S1 PC software, as shown in Figure 2The Px30 logic can be created using Boolean Equationsor a graphical interface as shown in figure 3.Figure 1> Independent <strong>Protection</strong> Settings GroupsUp to two setting groups are supported in the 20 Serieswhereas the 30 and 40 series can offer up to fourindependent setting groups. These can be activatedlocally, remotely or via a dedicated input and are used toallow for different system operating conditions and whereadaptive relaying is applied.> Measurement & Post Fault AnalysisFlexible logic for Px20The <strong>MiCOM</strong> Range of relays are capable of measuringand storing a wide range of system quantities such asCurrent, Voltage, Frequency, Power etc. depending on therelay functionality.All event, fault and disturbance records are time tagged toa resolution of 1ms using the internal real time clock andare stored in non-volatile memory. A supervised lithiumbattery ensures that the real time clock and records aremaintained during auxiliary supply interruptions.Where relays are communicating to a SCADA system,the protocols' telegrams can be used for external timesynchronization or alternatively an optional IRIG-B port isavailable for accurate time synchronization on all Px30and Px40 <strong>MiCOM</strong> relays.Some relays can also use an opto input to synchronizethe relay’s clock.Figure 2Programmable logic for Px40Figure 3Programmable logic for Px30

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!