13.07.2015 Views

AC-DC Single Output Power Module - TDK-Lambda

AC-DC Single Output Power Module - TDK-Lambda

AC-DC Single Output Power Module - TDK-Lambda

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

PFE1000FPFE1000F SpecificationsITEMS/UNITSInputMODEL PFE1000F-12 PFE1000F-28 PFE1000F-48Voltage Range (*2)(*3) V 85 - 265 V<strong>AC</strong>Frequency (*2) Hz 47 - 63<strong>Power</strong> Factor (*1)(*3) 0.95Efficiency (Typ) (*1) % 80 / 82 84 / 86Current (*1) A 9.8 / 4.8 13.6 / 6.6 13.4 / 6.5Inrush Current (Typ) (*1)(*3) A 20 / 40 peakNominal Voltage (*1) V<strong>DC</strong> 12 28 48Maximum Current A 60 36 21Maximum <strong>Power</strong> W 720 1008Voltage Setting Accuracy % +/-2<strong>Output</strong>Maximum Line Regulation mV 48 56 96Maximum Load Regulation mV 48 56 96Maximum Ripple & Noise (*3) mVp-p 120 280 480Voltage Adjustable Range % -20 / +20Over Current Protection (*4)(*5) 105% - 140%Over Voltage Protection (*5)(*1) At 100V<strong>AC</strong>/200V<strong>AC</strong> and maximum output power. (Baseplate Temperature = +25°C.)(*2) For cases where conformance to various safety specs (UL, CSA, EN) are required, input voltage range will be 100 - 240V<strong>AC</strong>(50/60Hz).(*3) External components are needed for operation. (Refer to basic connection and instruction manual.)(*4) Constant current limiting. (The unit automatically shutdown when left in OCP condition, with the output voltageless than the LVP level. Refer to instruction manual.)(*5) Reset : Line off or Control off. (Refer to instruction manual.)(*6) Refer to Instruction manual.(*7) Ambient Temperature min=-40°C(*8) Ratings - refer to Derating Curve.(*9) Heatsink has to be chosen according to Instruction manual.Derating Curve125% - 145% (Inverter shutdown method)Remote Sensing (*6) PossibleFunctionRemote ON/OFF Control (*6)PossibleParallel Operation (*6) PossibleSeries Operation (*6) PossibleOperating Temperature (*7)(*8) ℃ -40 - +100(Baseplate)Storage Temperature ℃ -40 - +100Operating Humidity % RH 20 - 95 (No Dewdrop)Storage Humidity % RH 10 - 95 (No Dewdrop)EnvironmentAt no operating, 10-55Hz (Sweep for 1min.)VibrationAmplitude 0.825mm constant (Maximum 49.0m/s²) X,Y,Z 1 hour eachShock196.1m/s²Cooling (*9) Conduction CooledInput-BaseplateWithstand VoltageIsolationIsolation ResistanceStandards Safety Standards: 2.5kV<strong>AC</strong>, Input-<strong>Output</strong> : 3.0kV<strong>AC</strong> for 1min.<strong>Output</strong>-Baseplate : 500V<strong>DC</strong> for 1min.<strong>Output</strong> to Baseplate 500V<strong>DC</strong> more than 100MΩ (25°C,70%RH)Approved by UL60950-1, CSA60950-1, EN60950-1Weight (Typ) g 500MechanicalSize (W x H x D) mm 100 x 13.4 x 160 (Refer to Outline Drawing)PFE1000F-12(720W)100Load(%)806040200-40 -20 0 20 40 60 80Baseplate Temperature(℃)100PFE1000F-28,48(1008W)100Load(%)80604085V<strong>AC</strong>≦Vin170V<strong>AC</strong>20170V<strong>AC</strong>≦Vin265V<strong>AC</strong>085-40 -20 0 20 40 60 80 100Baseplate Temperature(℃)・All contents are subject to change without notice.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!