13.07.2015 Views

SJ700 Series Brochure - Hitachi America, Ltd.

SJ700 Series Brochure - Hitachi America, Ltd.

SJ700 Series Brochure - Hitachi America, Ltd.

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Analog inputand othersMultispeed operation and JoggingV/f CharacteristicDC BrakingExternal frequencyadjustment Operation Mode and acceleration/deceleration function AVR PID ControlFrequency Upper/Lower Limit and Jump FrequencyCodeA013A014A015A016A017A019A020A220A320A021IA035A038A039A041A241A042A242A342A043A243A343A044A244A344A045A046A246A047A247A051A052A053A054A055A056A057A058A059A061A261A062A262A063A064A065A066A067A068A069A070A071A072A073A074A075A076A077A078A081A082A085A086A092A292A392A093A293A393A094A294A095A295A096A296A097A098A101A102A103A104Function NameMonitored data or settingDefault Setting-FE(CE) -FU(UL) -F(JP)O-L input active range start voltabeO-L input active range end voltabeO-L input active range start frequency selectionExternal frequency filter time constantEasy sequence function selectionMultispeed operation selectionMultispeed frequency settingMultispeed frequency setting, 2nd motorMultispeed frequency setting, 3rd motorMultispeed 1-15 settingJog frequency setting0. to "[O]-[L] input active range end voltage" (%)"[O]-[L] input active range start voltage" to 100. (%)00 (external start frequency), 01 (0 Hz)1. to 30. or 31. (500 ms filter ±0.1 Hz with hysteresis)00 (disabling), 01 (enabling)00 (binary: 16 speeds selectable with 4 terminals), 01 (bit: 8 speeds selectable with 7 terminals)0.0 or Òstart frequencyÓ to Òmaximum frequencyÓ (Hz)0.0 or Òstart frequencyÓ to Òmaximum frequency, 2nd motorÓ (Hz)0.0 or Òstart frequencyÓ to Òmaximum frequency, 3rd motorÓ (Hz)0.0 or Òstart frequencyÓ to Òn-th maximum frequencyÓ (Hz)"Start frequency" to 9.99 (Hz)00 (free-running after jogging stops [disabled during operation]), 01 (deceleration and stop after jogging0.100.0131.00000.000.000.000.001.000.100.0131.00000.000.000.000.001.000.100.0131.00000.000.000.000.001.00Jog stop modestops [disabled during operation]), 02 (DC braking after jogging stops [disabled during operation]),03 (free-running after jogging stops [enabled during operation]), 04 (deceleration and stop after joggingstops [enabled during operation]), 05 (DC braking after jogging stops [enabled during operation])00 00 00Torque boost method selectionTorque boost method selection, 2nd motorManual torque boost valueManual torque boost value, 2nd motorManual torque boost value, 3rd motorManual torque boost frequency adjustmentManual torque boost frequency adjustment, 2nd motorManual torque boost frequency adjustment, 3rd motorV/F characteristic curve selection, 1st motorV/F characteristic curve selection, 2nd motorV/F characteristic curve selection, 3rd motorV/f gain settingVoltage compensation gain setting for automatic torque boost. 1st motorVoltage compensation gain setting for automatic torque boost, 2nd motorSlippage compensation gain setting for automatic torque boost, 1st motorSlippage compensation gain setting for automatic torque boost, 2nd motorDC braking enableDC braking frequency settingDC braking wait timeDC braking force during decelerationDC braking time for decelerationDC braking/edge or level detection for [DB] inputDC braking force for startingDC braking time for startingDC braking carrier frequency settingFrequency upper limit settingFrequency upper limit setting, 2nd motorFrequency lower limit settingFrequency lower limit setting, 2nd motorJump (center) frequency setting 1Jump (hysteresis) frequency width setting 1Jump (center) frequency setting 2Jump (hysteresis) frequency width setting 2Jump (center) frequency setting 3Jump (hysteresis) frequency width setting 3Acceleration stop time frequency settingAcceleration stop time frequency settingPID function enablePID proportional gainPID integral time constantPID derivative gainPV scale conversion00(Manual torque boost) / 01(Automatic torque boost)00(Manual torque boost) / 01(Automatic torque boost)0.0 to 20.0 (%)0.0 to 20.0 (%)0.0 to 20.0 (%)0.0 to 50.0 (%)0.0 to 50.0 (%)0.0 to 50.0 (%)00 (VC), 01 (VP), 02 (free V/f), 03 (sensorless vector control), 04 (0Hz-range sensorless vector), 05 (vector with sensor)00 (VC), 01 (VP), 02 (free V/f), 03 (sensorless vector control), 04 (0Hz-range sensorless vector)00(VC), 01(VP)20. to 100. (%)0. to 255.0. to 255.0. to 255.0. to 255.00 (disabling), 01 (enabling), 02 (set frequency only)0.00 to 99.99, 100.0 to 400.0 (Hz)0.0 to 5.0 (s)0. to 100. (%)0.0 to 60.0 (s)00 (edge operation), 01 (level operation)0. to 100.(%)0.0 to 60.0(s)0.5 to 15.0(kHz)0.00 or "1st minimum frequency limit" to "maximum frequency" (Hz)0.00 or "2nd minimum frequency limit" to "maximum frequency, 2nd motor" (Hz)0.00 or "start frequency" to "maximum frequency limit" (Hz)0.00 or "start frequency" to "maximum frequency, 2nd motor limit" (Hz)0.00 to 99.99, 100.0 to 400.0 (Hz)0.00 to 10.00 (Hz)0.00 to 99.99, 100.0 to 400.0 (Hz)0.00 to 10.00 (Hz)0.00 to 99.99, 100.0 to 400.0 (Hz)0.00 to 10.00 (Hz)0.00 to 99.99, 100.0 to 400.0 (Hz)0.0 to 60.0 (s)00 (disabling), 01 (enabling), 02 (enabling inverted-data output)0.2 to 5.00.0 to 999.9, 1000. to 3600.0 (s)0.00 to 99.99, 100.0 (s)0.01 to 99.9900001.01.01.05.05.05.0000000100.100.100.100.100.000.500.000.0010.0.05.00.000.000.000.000.000.500.000.500.000.500.000.0001.01.00.001.0000001.01.01.05.05.05.0000000100.100.100.100.100.000.500.000.0010.0.05.00.000.000.000.000.000.500.000.500.000.500.000.0001.01.00.001.0000001.01.01.05.05.05.0000000100.100.100.100.100.000.500.000.0010.0.05.00.000.000.000.000.000.500.000.500.000.500.000.0001.01.00.001.00PV source settingOutput of inverted PID deviationPID variation rangeAVR function selectAVR voltage selectOperation mode selectionEnergy saving mode tuningAcceleration (2) time settingAcceleration (2) time setting, 2nd motorAcceleration (2) time setting, 3rd motorDeceleration (2) time settingDeceleration (2) time setting, 2nd motorDeceleration (2) time setting, 3rd motorSelect method to switch to Acc2/Dec2 profileSelect method to switch to Acc2/Dec2, 2nd motorAcc1 to Acc2 frequency transition pointAcc1 to Acc2 frequency transition point, 2nd motorDec1 to Dec2 frequency transition pointDec1 to Dec2 frequency transition point, 2nd motorAcceleration curve selectionDeceleration curve selectionOI-L input active range start frequencyOI-L input active range end frequencyOI-L input active range start currentOI-L input active range end current00 (input via OI), 01 (input via O), 02 (external communication),03 (pulse-string frequency input), 10 (operation result output)00(OFF), 01 (ON)0.0 to 100.0 (%)00 (always on), 01 (always off), 02 (off during deceleration)000.000000.000000.000200 V class: 200, 215, 220, 230, 240 (V) 400 V class: 380, 400, 415, 440, 460, 480 (V) 230/460 230/400 200/40000(Normal operation)/ 01(Energy-saving operation)/ 02(Fuzzy operation)0.1 to 100.00.01 to 99.99, 100.0 to 999.9, 1000. to 3600. (s)0.01 to 99.99, 100.0 to 999.9, 1000. to 3600. (s)0.01 to 99.99, 100.0 to 999.9, 1000. to 3600. (s)0.01 to 99.99, 100.0 to 999.9, 1000. to 3600. (s)0.01 to 99.99, 100.0 to 999.9, 1000. to 3600. (s)0.01 to 99.99, 100.0 to 999.9, 1000. to 3600. (s)00 (switching by 2CH terminal), 01 (switching by setting), 02 (switching only when rotation is reversed)00 (switching by 2CH terminal), 01 (switching by setting), 02 (switching only when rotation is reversed)0.00 to 99.99, 100.0 to 400.0 (Hz)0.00 to 99.99, 100.0 to 400.0 (Hz)0.00 to 99.99, 100.0 to 400.0 (Hz)0.00 to 99.99, 100.0 to 400.0 (Hz)00 (linear), 01 (S curve), 02 (U curve), 03 (inverted-U curve), 04 (EL-S curve)00 (linear), 01 (S curve), 02 (U curve), 03 (inverted-U curve), 04 (EL-S curve)0.00 to 99.99, 100.0 to 400.0 (Hz)0.00 to 99.99, 100.0 to 400.0 (Hz)0. to "[OI]-[L] input active range end current" (%)"[OI]-[L] input active range start current" to 100. (%)0050.015.0015.0015.0015.0015.0015.0000000.000.000.000.0000000.000.0020.100.0050.015.0015.0015.0015.0015.0015.0000000.000.000.000.0000000.000.0020.100.0050.015.0015.0015.0015.0015.0015.0000000.000.000.000.0000000.000.0020.100.0000= Allowed = Not permitted00Settingduring operation(allowed or not)Changeduring operation(allowed or not)15

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!