Decontamination in primary care dental practices - Gov.uk
Decontamination in primary care dental practices - Gov.uk
Decontamination in primary care dental practices - Gov.uk
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
12 Installation, validation, ma<strong>in</strong>tenance and test<strong>in</strong>g of sterilizers12 Installation, validation, ma<strong>in</strong>tenance andtest<strong>in</strong>g of sterilizersMa<strong>in</strong>tenance and servic<strong>in</strong>g12.1 The sterilizer should be ma<strong>in</strong>ta<strong>in</strong>ed and serviced <strong>in</strong>accordance with the manufacturer’s <strong>in</strong>structions.Validation and test<strong>in</strong>g12.2 Validation is needed for new equipment at<strong>in</strong>stallation and annually thereafter. It will also benecessary to validate equipment after any majorrepairs have been carried out. Manufacturers’guidance on validation should be followed.12.3 The follow<strong>in</strong>g type-tests or works tests will berequired.EuropeanNorm(EN)referenceB S N Manufacturer EN 13060Test Type Performed byDynamic chamberpressureAir leakage B S Manufacturer EN 13060Empty chamber B S N Manufacturer EN 13060Solid loadNon-wrappedS<strong>in</strong>gle-wrappedDouble-wrappedN SSB SManufacturer EN 13060Small porous itemsS<strong>in</strong>gle-wrappedDouble-wrappedSmall porous loadS<strong>in</strong>gle-wrappedDouble-wrappedFull porous loadS<strong>in</strong>gle-wrappedDouble-wrappedSSSB SSB SManufacturer EN 13060Manufacturer EN 13060Manufacturer EN 13060Hollow load B S Manufacturer EN 13060Solid load drynessNon-wrappedS<strong>in</strong>gle-wrappedDouble-wrappedSSB SManufacturer EN 13060Small porousitems: drynessS<strong>in</strong>gle-wrappedDouble-wrappedSSManufacturer EN 13060Test Type Performed bySmall porous load:drynessS<strong>in</strong>gle-wrappedDouble-wrappedFull porous load:drynessS<strong>in</strong>gle-wrappedDouble-wrappedSSSB SEuropeanNorm(EN)referenceManufacturer EN 13060Manufacturer EN 13060Residual air S N Manufacturer EN 13060Microbiological test B S N Manufacturer EN 13060(optional)Note: Immediately after <strong>in</strong>stallation, the air leakage andempty chamber tests should be undertaken by theCompetent Person (<strong>Decontam<strong>in</strong>ation</strong>) or serviceeng<strong>in</strong>eer.12.4 Tests not def<strong>in</strong>ed <strong>in</strong> the referred Standards arefurther def<strong>in</strong>ed <strong>in</strong> Chapter 15.Periodic tests12.5 The follow<strong>in</strong>g test<strong>in</strong>g protocol is recommended.Additional tests as def<strong>in</strong>ed by the manufacturershould also be performed.NoteUsers and operators (when delegated) should receivethe appropriate tra<strong>in</strong><strong>in</strong>g before carry<strong>in</strong>g out any ofthese tests. This tra<strong>in</strong><strong>in</strong>g should be documented onpersonal tra<strong>in</strong><strong>in</strong>g records.The Registered Manager should liaise with theequipment manufacturer with regard to tra<strong>in</strong><strong>in</strong>g.55