Decontamination in primary care dental practices - Gov.uk
Decontamination in primary care dental practices - Gov.uk
Decontamination in primary care dental practices - Gov.uk
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>Decontam<strong>in</strong>ation</strong>: Health Technical Memorandum 01-05 – <strong>Decontam<strong>in</strong>ation</strong> <strong>in</strong> <strong>primary</strong> <strong>care</strong> <strong>dental</strong> <strong>practices</strong> (2013 edition)Periodic tests14.3 The follow<strong>in</strong>g test<strong>in</strong>g protocol is recommended.Additionally any additional tests def<strong>in</strong>ed by themanufacturer should also be performed.Test Description Performed by ReferenceDAILYRemove and clean stra<strong>in</strong>ersand filtersEnsures filters and stra<strong>in</strong>ersare cleanUser or, by delegation,OperatorManufacturerDra<strong>in</strong> mach<strong>in</strong>e at end of day/sessionClean<strong>in</strong>g efficacyEnsures contam<strong>in</strong>ated water isnot stored <strong>in</strong> tankVisual exam<strong>in</strong>ation of all loaditemsUser or, by delegation,OperatorUser or, by delegation,OperatorWEEKLY<strong>in</strong>clud<strong>in</strong>g daily tests plus:Safety checks Check condition of door-seal User or, by delegation,OperatorProte<strong>in</strong> residue testConfirms that clean<strong>in</strong>gprocess reta<strong>in</strong>s the capabilityof remov<strong>in</strong>g prote<strong>in</strong>User or, by delegation,OperatorManufacturerManufacturerManufacturerParagraphs 15.14–15.18BS EN ISO 15883:1QUARTERLY (or to manufacturers’ recommendations)<strong>in</strong>clud<strong>in</strong>g weekly tests plus:Automatic control test CP(D)/service eng<strong>in</strong>eer BS EN ISO 15883:1Verification of calibration CP(D)/service eng<strong>in</strong>eer BS EN ISO 15883:1Clean<strong>in</strong>g efficacy test CP(D)/service eng<strong>in</strong>eer BS EN ISO 15883:1Ultrasonic activity test CP(D)/service eng<strong>in</strong>eer BS EN ISO 15883:1ANNUALLY<strong>in</strong>clud<strong>in</strong>g quarterly tests plus:Completion of all validationCP(D)/service eng<strong>in</strong>eer As abovetests aboveNoteFor clean<strong>in</strong>g efficacy tests and prote<strong>in</strong> residue tests, where the cycle does not have a r<strong>in</strong>se stage, items should be r<strong>in</strong>sed as a normalprocedure before these tests are carried out, otherwise the tests could return false positives.60