13.07.2015 Views

Decontamination in primary care dental practices - Gov.uk

Decontamination in primary care dental practices - Gov.uk

Decontamination in primary care dental practices - Gov.uk

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

14 Installation, validation, ma<strong>in</strong>tenance and test<strong>in</strong>g of ultrasonic cleaners14 Installation, validation, ma<strong>in</strong>tenance andtest<strong>in</strong>g of ultrasonic cleanersMa<strong>in</strong>tenance and servic<strong>in</strong>g14.1 The ultrasonic cleaner/irrigator should bema<strong>in</strong>ta<strong>in</strong>ed and serviced <strong>in</strong> accordance with themanufacturer’s <strong>in</strong>structions. However, <strong>in</strong> theabsence of these <strong>in</strong>structions, the schedulesoutl<strong>in</strong>ed <strong>in</strong> this chapter should be followed.Validation14.2 Validation is needed for new equipment at<strong>in</strong>stallation and annually thereafter. It will also benecessary to validate equipment after any majorrepairs have been carried out. Manufacturers’guidance on validation should be followed;alternatively, the follow<strong>in</strong>g protocol is suggested.(Tests not def<strong>in</strong>ed <strong>in</strong> the referred Standards aredef<strong>in</strong>ed <strong>in</strong> Chapter 15.)Test Description Performed by ReferenceVerification of calibration The accuracy of <strong>in</strong>dicat<strong>in</strong>gand record<strong>in</strong>g <strong>in</strong>struments isCP(D)/service eng<strong>in</strong>eer BS EN ISO 15883:1 andBS EN ISO 15883:2checked aga<strong>in</strong>st certificatedsource <strong>in</strong>strumentsAutomatic control test The values of cycle time andtemperature are noted atrelevant stages of the cycleso that a f<strong>in</strong>gerpr<strong>in</strong>t of theautomatic cycle can be made.CP(D)/service eng<strong>in</strong>eer Paragraphs 15.3–15.5Dra<strong>in</strong>age test (whereapplicable)Lid (ie door) <strong>in</strong>terlockFluid emissionChemical dos<strong>in</strong>g test (whereautomated)Clean<strong>in</strong>g efficacy testThermometric test (wheremach<strong>in</strong>e also dis<strong>in</strong>fects)Ultrasonic activity testEnsures free-flow<strong>in</strong>g dra<strong>in</strong>age CP(D)/service eng<strong>in</strong>eer BS EN ISO 15883:1 andBS EN ISO 15883:2Confirms safety to operatorand exposure to completecycle onlyConfirms door-sealprevents contam<strong>in</strong>ation tosurround<strong>in</strong>gsConfirms repeatable detergentadditionUs<strong>in</strong>g an artificial soil toclean a worst-case load, theexposure to ultrasonic activityfor a sufficient time period isconfirmedThermocouples are attachedto worst-case load to confirmthat dis<strong>in</strong>fection parametersare acceptableThe use of alum<strong>in</strong>iumfoil with<strong>in</strong> the cleanertank <strong>in</strong>dicates a uniformdistribution of ultrasonicactivityA wand meter may be used aslong as po<strong>in</strong>ts of measurementare compatible with the foiltest and are fully recordedCP(D)/service eng<strong>in</strong>eerCP(D)/service eng<strong>in</strong>eerCP(D)/service eng<strong>in</strong>eerCP(D)/service eng<strong>in</strong>eerCP(D)/service eng<strong>in</strong>eerBS EN ISO 15883:1 andBS EN ISO 15883:2BS EN ISO 15883:1 andBS EN ISO 15883:2BS EN ISO 15883:1 andBS EN ISO 15883:2BS EN ISO 15883:1 andBS EN ISO 15883:2BS EN ISO 15883:1 andBS EN ISO 15883:2CP(D)/service eng<strong>in</strong>eer Paragraphs 15.6–15.1359

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!