04.12.2012 Views

C-13872 Instruction E44 Owner's Manual.pdf - Enviro

C-13872 Instruction E44 Owner's Manual.pdf - Enviro

C-13872 Instruction E44 Owner's Manual.pdf - Enviro

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

28<br />

Initial Installation<br />

TO TEST VALVE PRESSURES (INPUT RATES):<br />

QUALIFIED INSTALLERS ONLY<br />

The pressure taps are located on the front side of the valve (see Figure 35).<br />

1. Using a long flat bladed screwdriver, turn set screw counter-clockwise to loosen.<br />

2. Place 5 /16 in (8 mm) I.D. hose over the pressure taps.<br />

3. Check pressures using a manometer.<br />

4. When finished, remove hose and tighten set screw.<br />

Always check for gas leaks with a soap and water solution after completing the required<br />

pressure test.<br />

1<br />

NEVER USE AN OPEN FLAME FOR LEAK TESTING.<br />

2 3<br />

Figure 35: Valve Details.<br />

Item number DescrIptIon<br />

1 Pilot Adjustment<br />

Screw<br />

2 Inlet Pressure Test<br />

Point<br />

3 Outlet Pressure Test<br />

Point<br />

Table 6: Valve Details.