C-13872 Instruction E44 Owner's Manual.pdf - Enviro
C-13872 Instruction E44 Owner's Manual.pdf - Enviro
C-13872 Instruction E44 Owner's Manual.pdf - Enviro
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
aDjusting the piLot fLame:<br />
The pilot flow adjustment is set to maximum at the factory and should not need to be adjusted. The pilot<br />
flame should envelope ⅜” to ½” (10 to 13mm) of the thermocouple (see Figure 36). However, should<br />
the need arise, follow Steps 1- 2 below.<br />
1. The adjustment screw can be reached through the front of the<br />
unit using a 10 inch long blade head screw driver (see Figure 35<br />
for location on valve).<br />
2. Turn the adjustment screw clockwise to decrease or<br />
counterclockwise to increase pilot flame.<br />
switching to continuous piLot moDe:<br />
Initial Installation<br />
QUALIFIED INSTALLERS ONLY<br />
Proper Flame<br />
Adjustment<br />
3/8”- 1/2”<br />
(10-13mm)<br />
Thermocouple<br />
Figure 36: Proper Pilot Flame.<br />
In cold climates, it may be required to run the pilot continuously to keep the vent termination from<br />
freezing up. Flip the toggle switch on the bottom right of the unit to switch between intermittent and<br />
continuous pilot.<br />
Figure 37: Pilot Mode Toggle Switch.<br />