Instructions manual <strong>SE</strong> series4. ELECTRICAL CONNECTION<strong>SE</strong>very electrical connection to the emitter and receiving units is madethrough a male M12 connector, located in the lower part of the safetylight curtain.A M12 8-pole connector is used for the receiver and a M12 4-poleconnector for the emitter.OSSD1 PNPOSSD2 PNP6540V73+24Vdc182+24Vdc+VdcRECEIVER (RX): 1 = white = TEST/START2 = brown = +Vdc3 = green = MUTING 14 = yellow = MUTING 25 = grey = OSSD1 16 = pink = OSSD2 27 = blue = 0V8 = red = LAMPN.A.2 1+Vdc0V3 4N.A.EMITTER (TX): 1 = brown = +Vdc3 = blue = 0V19