Alert - 2 SeriesAPPENDIX - DHigh Pressure Shuttle ValveHigh pressure shuttle valves M2-SHUTV-HP are used only in Nitrogen manifolds.A repair kit is <strong>com</strong>prised of: 1 O-ring M2-X-HPV-052 O-rings M2-X-LPV-081 O-ring M2-X-HPV-092 Seats M2-X-LPV-SEATLubricant Krytox GreaseMAINTENANCE PROCEDUREDismantling the Shuttle Valve1. Remove the three socket head cap screws from the body.2. Gently separate the two body halves.3. Remove the piston shaft assembly.4. Unscrew the lock nut (Item #1) from the shaft assembly. Remove the seats (Item #2) and valve(Item #3) piston.5. Extract o-rings from their grooves using a fine pointed instrument (needle), being careful not toscratch the brass body halves.6. Discard the o-rings and seats.231Page: 33