13.07.2015 Views

CSA HD Manifold Manual 5.0(2) - KSM-MEDICAL.com

CSA HD Manifold Manual 5.0(2) - KSM-MEDICAL.com

CSA HD Manifold Manual 5.0(2) - KSM-MEDICAL.com

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Alert - 2 SeriesAPPENDIX - OLiquid Cylinder ApplicationsThe Liquid by Liquid manifold is specifically designed to regulate and monitor vaporized gas from cryogenicliquid cylinders. The manifold incorporates special cryogenic regulators to prevent regulator freeze up underhigh-flow conditions. To prevent the loss of useful gas into the atmosphere, an economizer circuit is includedto utilize the accumulated excess pressure from the secondary supply bank. The economizer circuit reroutes theexcess pressure into the line via check valves inserted in the main inlet blocks, then passes through the 0.007”orifice which goes into the main centre section of the manifold. The <strong>Manifold</strong> shall be a digital, fully automatic type and shall switch from "Bank In Use" to "Reserve" bank withoutfluctuation in the supply line pressure and without the need for external power. After the switch-over, the"Reserve" bank shall then be<strong>com</strong>e the "Bank in Use" and the "Bank in Use" shall be<strong>com</strong>e the "Reserve" bank.When change-over occurs, the ‘Push to Test’ button must be pressed to re-set the manifold into “Ready” mode.The manifold will be powered by a microprocessor located behind the front door panel.Page: 45

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!