20.07.2015 Views

PhD Thesis - staffweb - University of Greenwich

PhD Thesis - staffweb - University of Greenwich

PhD Thesis - staffweb - University of Greenwich

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

APPENDIX 1 : SMARTFIRE VERIFICATION AND VALIDATION REPORT1 INTRODUCTION................................ ................................ ................................ ................................ 32 GENERAL PHYSICS VALIDATION CASES................................ ................................ ................... 42.1 BASIC PHYSICS VERIFICATION OF SMARTFIRE — CONVECTIVE TERM.............................................42.1.1 SMARTFIRE results................................ ................................ ................................ ................42.2 RADIATION VERIFICATION IN 2D CAVITY WITHOUT FLOW. ................................................................52.2.1 SMARTFIRE results................................ ................................ ................................ ................62.3 SYMMETRY BOUNDARY CONDITION TEST.......................................................................................102.3.1 SMARTFIRE results................................ ................................ ................................ ..............102.4 TWO-DIMENSIONAL TURBULENT FLOW OVER A BACKWARD FACING STEP.........................................122.4.1 Results................................ ................................ ................................ ................................ ..122.5 TURBULENT LONG DUCT FLOW.......................................................................................................152.5.1 Results................................ ................................ ................................ ................................ ..162.6 TURBULENT BUOYANCY FLOW IN A CAVITY....................................................................................172.6.1 Results................................ ................................ ................................ ................................ ..183 FIRE VALIDATION CASES................................ ................................ ................................ ............ 233.1 STECKLER ROOM FIRE...................................................................................................................233.1.1 Results................................ ................................ ................................ ................................ ..243.2 HONG KONG AIRPORT CASE..........................................................................................................263.3 SIMULATIONS FOR LPC-RUN-007................................................................................................. 283.3.1 Results................................ ................................ ................................ ................................ ..293.4 COMPARISON OF RUN-TIMES BETWEEN PHOENICS AND SMARTFIRE..........................................323.5 SIMULATION OF STECKLER ROOM FIRE USING LARGE CELL BUDGET.................................................333.5.1 Results................................ ................................ ................................ ................................ ..334 REFERENCES................................ ................................ ................................ ................................ ...36Appendix 11.1 Page 141-2 2

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!