APPENDIX 1 : SMARTFIRE VERIFICATION AND VALIDATION REPORT1400temp (K)temp <strong>of</strong> 30 cm below the ceilingtime 110s12001000800600400200flow3dsmartfiredist from the left edge (m)00.0 1.0 2.0 3.0 4.0 5.0Figure 31 -Temperature pr<strong>of</strong>ile across the cabin 0.3m below the ceiling.1600temp (K)temp in fire plumetime 110s140012001000800600flow3d400smartfire200height (m)00.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5Figure 32 -Vertical temperature pr<strong>of</strong>ile in the centre <strong>of</strong> the fire.From the above figures it can be seen that both SMARTFIRE and FLOW3D produce verysimilar results.Appendix 11.1 Page 141-27 27