APPENDIX 1 : SMARTFIRE VERIFICATION AND VALIDATION REPORT2.3 Symmetry boundary condition testThis case is intended to test if the symmetry function works correctly. The case involvesflow expansion from a small duct into a larger duct. The configuration is shown in Figure 7below. The case was simulated using the whole flow domain and then repeated using asymmetry boundary condition along the central axis.Figure 7 - Expanding duct with symmetry line indicated2.3.1 SMARTFIRE resultsThe flow fields <strong>of</strong> the symmetry case (Figure 8) and whole field case (Figure 9) systems areplotted below. The velocity pr<strong>of</strong>ile at the outlet is plotted in Figure 10.Figure 8 -The flow field producted by the simulation using the half systemAppendix 11.1 Page 141-10 10