16 Finalizing the <strong>Installation</strong> (for qualified installers only)Electrical Connection (required)• The electrical line to the grounded receptacle inside the fireplace must be installed by aqualified installer and must meet all local codes.• Make sure the household breaker is shut off prior to working on any electrical lines.• The fireplace must be properly grounded in accordance with local codes (or ANSI/NFPA 70-1987)• The electrical line must be a min. 14 gauge, and supply 120 Volts at 60 Hz (2 Amps)Caution:Label all wires prior to disconnection when servicing controls. Wiring errors can causeimproper and dangerous operation.Grounded ReceptacleLeft Side of <strong>Fireplace</strong>Junction Box AssemblyReceptacle Cover PlateGrounded 110VPower SupplyStrain ReliefTravis Industries 4071126 100-01195_000