21.07.2015 Views

M/s. Gupta Infrastructure (India) Private Limited, 7th ... - Seiaacg.org

M/s. Gupta Infrastructure (India) Private Limited, 7th ... - Seiaacg.org

M/s. Gupta Infrastructure (India) Private Limited, 7th ... - Seiaacg.org

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Selection of Mate{iali fgr Better Ene{ctv, Efiigign,cJ: -i ,.:i):Use of fly ash based brickslblocks/tiles/products shall be exptored to themaximum extent possible. Blended cemeni with fly ash shall be used (not lessthan 17%). The provisions of Ministry of Fnvironment and Forests, Governmentof lndia Notification No 763(E) dated 14l}glj999 [amended notification no. SO979 (E) dated 27lA8l20A3l regarding use of Fly ash must be comptied with.Appropriate usage of other industrial wastes shall also be explored. Soil borrowarea should be filled up with ash with proper compaction and covered withtopsoil kept separately. Fly ashlpond ash should be used for low- lying areasfilling. ln embankinents/road construction etc. ash should be utilized as perguidelines of Ministry of Environment and Forests, Government of lndia/Cerrtral Potlution Control Board/ lndian Road Congress etc. concerningauthorities. The use of perforated brick / hollow blocks / fly ash basedlightweight aerated concrete etc. should also be explored so as to reduce loadon natural resources.ii) Construction shall conform to the requirements of local seismic regulations.The project proponent shall obtain permission for the plans and designsincluding structural design, standard, safety, adequacy of firefightingequipments, protection measures for lightning and specifications of alliii)iv)v)vi)construction works from concerned authority.Reduce the use of glazed surface as per National Building Code 2005. Use ofglass in various buildings may be reduced up to 40% to reduce the electricityconsumption and load on air-conditioning. lf necessary, use of high qualitydouble glass with special reflective coating in windows. Roof of the variousbuildings should meet prescriptive requirement as per Energy ConservationBuilding Code by using appropiiate thermal insulation material to fulfilrequirement. opaque wall should meet prescriptive requirement as per EnergyConservation Building Code which is proposed to be mandatory for all airconditioned spaces while it is inspirational for non-air-conditioned spaces byuse of appropriate thermal jnsulation material to fulfil requirement.Use of energy eificient construction materials to achieve the desired thermalcomfort shall be incorporated. The desired level of roof assembling 'U' factorand insulation 'R' value must be achieved. Roof assembling 'U' factor for thetop roof shall not exceed 0.4 watvsq.m/degree centigrade with appropriatemodifications of specifications and building technologies. The provisions ofNational Building Code 2005 shall be strictly followed.Modern electrical power transmission & distribution system shall be installed.street lighting shall be energy efficient. The High Pressure Sodium Vapour(HPSV) Lamps & C,ompact Fluqresc6nt Lamps (CFL) along the buildingnetwork system svii)viii)Extensive networK oirl#uuiaa pnon6,s.,-#d rinorines shail be providec. rnetelephone and elditricrcAbles etdptriq,tabtes.t .'i, shall shail,]bg,ijbiO'.i berijSid - 7.,. t- - in the same corrldor. Adeauate Adequate---r---vertical and horizontal:sgparafion b'etween telephone and electric cable shall be1.,maintained.Reduce hard paving-onsite (open ar:pa area surrounding building premises) and/orprovide shade on' hard paved surfaces to minimize heat island effect andimperviousness of the site.C lue6s{Ocslrqr,EC lirer\Cupra lBfr6ltuctsc (gurldin8 Cmtra|on) ds(-,

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!