20.08.2015 Views

Drive technology for AC and DC

Drive technology for AC and DC

Drive technology for AC and DC

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

L7)Electrical connection Vario<strong>Drive</strong> CSize 084/112Technical features:• L7 = PFC (active) / L6 = PFC (passive) • Alarm relay• Integrated PID controller • Line undervoltage detection• Control input 0-10 V<strong>DC</strong> / PWM • only L6 = Phase failure detection• Input <strong>for</strong> sensor 0-10 V or 4-20 mA • Motor current limitation• Slave output 0-10 V max. 3 mA • Electronics / motor overtemperature protection• Output 20 V<strong>DC</strong> (±20 %) max. 50 mA • Locked-rotor protection• Output 10 V<strong>DC</strong> (+10 %) max. 10 mA • Soft start• RS485 ebmBUSVARIODRIVE In<strong>for</strong>mationVARIODRIVE CompactKL3 KL2 KL1RS ARS BRS ARS BGND0-10 VPWM4-20 mA+20 V+10 V0-10 VPWMGNDOUTConnector Connection Assignment / function Connector Connection Assignment / functionPEPE Protective earth KL3 OUT Master output 0-10 V max. 3 mAKL1 N Mains 50/60 Hz. neutralGND GNDLMains 50/60 Hz, phase0-10 V / PWM Control / Actual value input (Impedance 100 kΩ)KL2 NCCOMAlarm relay, break <strong>for</strong> failureAlarm relay, COMMON (2A, 250 V<strong>AC</strong>, <strong>AC</strong>1)+10 V Supply <strong>for</strong> external potentiometer,10 V<strong>DC</strong> (+10 %) max. 10 mANOAlarm relay, make <strong>for</strong> failure+20 V Supply <strong>for</strong> external sensor,20 V<strong>DC</strong> (±20 %) max. 50 mA4-20 mA Control / Actual value input0-10 V / PWM Control / Actual value inputGND GNDRSB RS485 interface <strong>for</strong> ebmBUS; RS BRSA RS485 interface <strong>for</strong> ebmBUS; RS ARSB RS485 interface <strong>for</strong> ebmBUS; RS BRSA RS485 interface <strong>for</strong> ebmBUS; RS ANOCOMNCLNPEVario<strong>Drive</strong> CECI motorBG motorL6)RS ARS BRS ARS BGND0-10 VPWMKL3 KL2 KL14-20 mA+20 V+10 V0-10 VPWMGNDOUTNOCOMNCL1L2L3PEBCI motorConnector Connection Assignment / function Connector Connection Assignment / functionPEPE Protective earth KL3 OUT Master output 0-10 V max. 3 mAKL1 L3 Mains; L3GND GNDL2Mains; L20-10 V / PWM Control / Actual value input (Impedance 100 kΩ)L1Mains; L1+10 V Supply <strong>for</strong> external potentiometer,KL2 NCCOMAlarm relay, break <strong>for</strong> failureAlarm relay, COMMON (2A, 250 V<strong>AC</strong>, <strong>AC</strong>1)+20 V10 V<strong>DC</strong> (+10 %) max. 10 mASupply <strong>for</strong> external sensor,NOAlarm relay, make <strong>for</strong> failure20 V<strong>DC</strong> (±20 %) max. 50 mA4-20 mA Control / Actual value input0-10 V / PWM Control / Actual value inputGND GNDRSB RS485 interface <strong>for</strong> ebmBUS; RS BRSA RS485 interface <strong>for</strong> ebmBUS; RS ARSB RS485 interface <strong>for</strong> ebmBUS; RS BRSA RS485 interface <strong>for</strong> ebmBUS; RS A<strong>AC</strong> motorsSpecifications71Representatives

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!