Liebert Deluxe System/3 - DX
Liebert Deluxe System/3™ - DX
Liebert Deluxe System/3™ - DX
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
InstallationFigure 9Electrical field connectionsField-supplied disconnect switch when factory-installedunit disconnect switch is not providedFactory-installed unitdisconnect switch (optional)Monitoring panel3-phaseelectricservicenot by<strong>Liebert</strong>3-phase connection; electricservice connection terminalswhen factory disconnect switchis suppliedFactory-installed disconnectswitch (optional)Smoke detector alarmconnections; field-supplied 24V;Class 2 wire to remote alarmcircuits; factory-wired contactsfrom optional smoke detector are#91-comm., #92-NO and #93-NCCommon alarm connection;field-supplied 24V; Class 2 wireto common alarm from pigtails75 +76, which arefactory-connected to commonalarm relay (R3)Electric handy boxfactory-installedwith coverHeat rejection connection;field-supplied 24V; Class 1 wiringto interlock heat rejection frompigtails 70 and 71, which arefactory-connected to compressorside switchesCondensate pump connection forpumps shipped loose; factory-suppliedwiring from pump to pigtails; fuses areinstalled on electric panelRemote unit shutdown; replace existingjumper between Terminals 37 and 38 witha normally closed switch having aminimum 50VA rating; use field-suppliedClass 1 wireField-wired to componentson electric panelElectric connection block3-phase connection; electric serviceconnection terminals when factorydisconnect switch is not suppliedEarth ground connection (60Hz);connection terminal for field-suppliedearth grounding wireEarth ground bar (50Hz only); connectionterminals with factory-ground from eachhigh-voltage component for field-suppliedearth grounding wire3-phase electric service not by <strong>Liebert</strong>Special alarm connections; field-supplied 24V, Class 1wire for special alarms; connections made by addingnormally open contact between terminals (24 & 50) forstandard microprocessor; advanced microprocessorhas four alarms at terminal: 24 & 50; 24 & 51; 24 & 55and 24 & 56Analog inputs; optional terminals 41 to 48 provideconnections for shielded, twisted-pair cable to asmany as four customer supplied analog sensors(AM and AG only)Site monitoring connection; terminals 77(-) and 78(+)are for connection of a 2-wire, twisted-paircommunication cable (available from <strong>Liebert</strong> orothers) to optional SiteScan and arefactory-connected to the interface board on the unitElectric conduit knockouts on bottom andrear of wire raceway; knockout sizes are1-3/8" (34.9mm) or 1-3/4" (44.5mm) or2-1/2" (63.5mm)DPN000538 Rev1NOTERefer to specification sheet for full load amp and wire size amp ratings.14