22.08.2015 Views

Liebert Deluxe System/3 - DX

Liebert Deluxe System/3™ - DX

Liebert Deluxe System/3™ - DX

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

InstallationFigure 9Electrical field connectionsField-supplied disconnect switch when factory-installedunit disconnect switch is not providedFactory-installed unitdisconnect switch (optional)Monitoring panel3-phaseelectricservicenot by<strong>Liebert</strong>3-phase connection; electricservice connection terminalswhen factory disconnect switchis suppliedFactory-installed disconnectswitch (optional)Smoke detector alarmconnections; field-supplied 24V;Class 2 wire to remote alarmcircuits; factory-wired contactsfrom optional smoke detector are#91-comm., #92-NO and #93-NCCommon alarm connection;field-supplied 24V; Class 2 wireto common alarm from pigtails75 +76, which arefactory-connected to commonalarm relay (R3)Electric handy boxfactory-installedwith coverHeat rejection connection;field-supplied 24V; Class 1 wiringto interlock heat rejection frompigtails 70 and 71, which arefactory-connected to compressorside switchesCondensate pump connection forpumps shipped loose; factory-suppliedwiring from pump to pigtails; fuses areinstalled on electric panelRemote unit shutdown; replace existingjumper between Terminals 37 and 38 witha normally closed switch having aminimum 50VA rating; use field-suppliedClass 1 wireField-wired to componentson electric panelElectric connection block3-phase connection; electric serviceconnection terminals when factorydisconnect switch is not suppliedEarth ground connection (60Hz);connection terminal for field-suppliedearth grounding wireEarth ground bar (50Hz only); connectionterminals with factory-ground from eachhigh-voltage component for field-suppliedearth grounding wire3-phase electric service not by <strong>Liebert</strong>Special alarm connections; field-supplied 24V, Class 1wire for special alarms; connections made by addingnormally open contact between terminals (24 & 50) forstandard microprocessor; advanced microprocessorhas four alarms at terminal: 24 & 50; 24 & 51; 24 & 55and 24 & 56Analog inputs; optional terminals 41 to 48 provideconnections for shielded, twisted-pair cable to asmany as four customer supplied analog sensors(AM and AG only)Site monitoring connection; terminals 77(-) and 78(+)are for connection of a 2-wire, twisted-paircommunication cable (available from <strong>Liebert</strong> orothers) to optional SiteScan and arefactory-connected to the interface board on the unitElectric conduit knockouts on bottom andrear of wire raceway; knockout sizes are1-3/8" (34.9mm) or 1-3/4" (44.5mm) or2-1/2" (63.5mm)DPN000538 Rev1NOTERefer to specification sheet for full load amp and wire size amp ratings.14

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!