22.08.2015 Views

Model YCAV Air-Cooled Screw Compressor Liquid Chillers Style A

Model YCAV Air-Cooled Screw Compressor Liquid Chillers ... - DCES

Model YCAV Air-Cooled Screw Compressor Liquid Chillers ... - DCES

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Accessories and Options - continuedFORM 201.21-EG1 (711)on the sides of the unit to visually screen and protectcoils. (Factory mounted)• LOUVERED PANELS (FULL UNIT) - Painted steelto match unit panels, to protect condenser coils fromincidental damage, visually screen internal components,and prevent unauthorized access to internalcomponents. (Factory mounted)• LOUVERED (CONDENSERS)/WIRE PANELS (ME-CHANICAL) - Louvered steel panels on external condensercoil faces, painted to match unit panels. Heavygauge, welded wire-mesh, coated to resist corrosion,around base of machine to restrict unauthorized access.(Factory mounted)EVAPORATOR OPTIONS• 1-1/2” Insulation - Double thickness insulation provided.(Factory mounted)• Raised Face Flange Accessory for cooler nozzles:♦ 150 psig (10.3 barg), welded flanges (field kit,matching pipe flange by contractor).♦ 300 psig (20.7 barg), welded flanges (factoryinstalled, matching pipe flange by contractor).♦ 150 psig (10.3 barg), ANSI/AWWA C-606 Flanges(field kit, matching pipe flange by contractor).FLOW SWITCH ACCESSORY - Vapor proof SPDT, NEMA3R switch, 150 psig (10.3 barg) DWP, 20°F to 250°F (-7°Cto 121°C) with 1” NPT (IPS) connection for upright mountingin horizontal pipe (This flow switch or equivalent mustbe furnished with each unit). (Field mounted)DIFFERENTIAL PRESSURE SWITCH - Alternative tothe paddle-type flow switch. The switch is rated at 3-45psig (0.2-3 barg) range and is equipped with 1/4" NPTEpressure connections. (Field mounted)BUILDING AUTOMATION SYSTEM INTERFACE - Thechiller is designed to accept 4 to 20mA or 0 to 10 VDCinput to reset the leaving chilled liquid temperature. (Factorymounted)MULTI-UNIT SEQUENCE CONTROL - Separate sequencingcontrol center provided to permit control of up toeight chillers in parallel based of mixed liquid temperature(interconnecting wiring by others). (Field mounted)VIBRATION ISOLATION OPTIONS• Elastomeric Isolation - Recommended for normalinstallations. It provides very good performance inmost applications for the least cost. (Field mounted)• 1” Spring Isolators - Level adjustable, spring andcage type isolators for mounting under the unit baserails. 1” nominal deflection may vary slightly by application.(Field mounted)• 2” Seismic Spring Isolators - Restrained Spring-FlexMountings incorporate rugged welded steel housingwith vertical and horizontal limit stops. Housings designedto withstand a minimum 1.0g accelerated forcein all directions to 2”. Level adjustable, deflection mayvary slightly by application. (Field mounted)BUY AMERICAN ACT COMPLIANCE - In keeping withthe “Buy America Act”, products will be comprised of 50%or more U.S. content and manufactured (final assembly)in the U.S.A.SERVICE ISOLATION VALVE - Service suction isolationadded to unit for each refrigerant circuit. (Factorymounted)CHICAGO CODE RELIEF VALVE - Special relief valvesper the Chicago code. (Factory mounted)SEQUENCE CONTROL AUTOMATIC LEAD TRANS-FER - Provided to permit control of up to eight chillersin parallel based on mixed liquid temperature (Fieldmounted)8JOHNSON CONTROLS

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!