5.0 Fault finding<br />

Burner<br />

fails to<br />

light<br />

Electric<br />

Supply ON<br />

No<br />

Turn on Electric<br />

Supply<br />

Yes<br />

Check fuse Replace if<br />

required<br />

Yes<br />

Flue fan running<br />

No<br />

Check flue fan<br />

connections<br />

Yes<br />

Replace flue fan<br />

Yes<br />

Air pressure<br />

switch made<br />

No<br />

Check flue is clear<br />

Yes<br />

Change air<br />

pressure switch<br />

d<br />

Yes<br />

Thermostat<br />

calling for<br />

heat<br />

Yes<br />

Limit thermostat<br />

operated<br />

Yes<br />

Reset Limit<br />

thermostat<br />

Yes<br />

Gas Supply<br />

ON<br />

No<br />

Turn on Gas<br />

Supply<br />

Yes<br />

Air in Gas<br />

Supply<br />

Yes<br />

Purge Gas Line<br />

No<br />

Spark ignition<br />

on<br />

No<br />

Check HT leads<br />

and<br />

connections<br />

Yes<br />

Faulty control<br />

box<br />

Yes<br />

No flame<br />

Yes<br />

Faulty Gas<br />

valve<br />

Yes<br />

Change gas<br />

valve<br />

26