Panasonic Air Conditioner
Panasonic Air Conditioner
Panasonic Air Conditioner
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
12.3.5 Automatic Restart Control<br />
When the power supply is cut off during the operation of air conditioner, the compressor will re-operate within three to<br />
four minutes after power supply resumes.<br />
12.3.6 Indication Panel<br />
LED POWER TIMER<br />
Color Green Orange<br />
Light ON Operation ON Timer setting ON<br />
Light OFF Operation OFF Timer setting OFF<br />
Note:<br />
� If POWER LED blinks, the possible operation of the unit is operation mode judgment, or ON timer<br />
sampling.<br />
�� If Timer LED blinks, there is an abnormal operation occurs.<br />
12.3.7 Timer control<br />
Delay ON Timer ca be set using remote controller, the unit with timer set will start operate earlier than the setting time.<br />
This is to provide a comfortable environment when reaching the set On time. Seventy minutes before the set time for<br />
ON Timer or ON-OFF Timer setting, indoor ( at fan speed of Lo-) and outdoor fan motor start operate for 30 seconds<br />
to determine the indoor intake air temperature and outdoor air temperature in order to judge the operation mode.<br />
From the above judgment, the decided operation will start operate earlier than the set time as shown below.<br />
Timer Signal Receiving sound During Operation.<br />
Timer Signal Receiving Sound When the <strong>Air</strong> <strong>Conditioner</strong> Stops.<br />
35<br />
35