13.2.2 Freeze Prevention Control<br />

1 .Frequency of the compressor<br />

For prevention of freezing of the indoor evaporator, the frequency of the compressor will be changed according<br />

to the indoor piping temperature.<br />

2 .Indoor Fan Control<br />

Indoor fan speed changes according to the indoor piping temperature.<br />

13.2.3 Dew Prevention Control<br />

To prevent dew formation at indoor unit discharge area.<br />

This control starts if all conditions continue for 20 minutes:<br />

- Operated with Cooling or Soft Dry Mode.<br />

- Indoor intake temperature is between 25� and 29�.<br />

- Outdoor air temperature is less than 30�.<br />

This control stopped then receive air swing change signal from Remote Control.<br />

13.2.4 Overload Protection For Cooling Operation<br />

The frequency for the compressor will change according to the outdoor piping temperature.<br />

RE9JKE, RE12JKE<br />

13.3 Indoor Piping <strong>Air</strong> Temperature Control (Heating)<br />

9�.<br />

8�.<br />

6�.<br />

0�.<br />

13.3.1 Indoor Fan Control<br />

1. Indoor fan is controlled by the indoor piping temperature.<br />

� Manual Fan Speed<br />

Piping Temperature(�)<br />

K0 K1 K2 K3 K4 K5 K6 K7 K8 K9 K10 K11<br />

16 19 24 32 32 36 36 39 54 54 57 60<br />

38<br />

Outdoor pipe Temp.<br />

63�.<br />

61�<br />

60�<br />

58�<br />

RE15JKE<br />

Max:40 Hz Min 30Hz<br />

56�