� Auto Fan Speed<br />
2. During heating operation, the indoor fan will run at the following speed when the compressor stops.<br />
3. Hot Start<br />
When the heating operation starts, the indoor fan stops and the compressor run with the frequency of 117Hz.<br />
This is to prevent the cold airflow from blowing.<br />
If the piping temperature rises to 19 �, and the indoor fan speed and airflow direction varies with the indoor piping<br />
temperature, the hot start control is completed.<br />
13.3.2 Overload Protection Control<br />
The frequency for the compressor is determined by indoor piping temperature.<br />
Indoor piping temp.<br />
Free<br />
+15rpm/s<br />
RE9JKE, RE12JKE<br />
Fixed<br />
K8<br />
K7<br />
460<br />
39<br />
60 �<br />
55 �<br />
52 �<br />
49 �<br />
Stop<br />
8Hz/15’’ down<br />
1Hz/15’’ down<br />
110 Hz,~ 35Hz<br />
Free<br />
RE15JKE<br />
110 Hz,~ 35Hz<br />
46 �