8.6. Random Auto Restart Control<br />
• If there is a power failure during air conditioner operation, operation will be automatically restarted after 3 to 4 minutes when the<br />
power is resumed.<br />
It will start with previous operation mode and airflow direction.<br />
• Restart time is decided randomly using 4 parameter:-<br />
Intake air temperature, setting temperature, fan speed and Air Swing Blade position.<br />
• Auto Restart Control is not available when Timer is set.<br />
• This control can be omitted by open the circuit of JX2. (Refer Circuit Diagram)<br />
8.7. Airflow Direction Control<br />
Vertical Airflow Direction Auto-Control<br />
• When set an Airflow Direction Auto-Control with remote<br />
control, the louver swings up and down as shown in the<br />
diagram.<br />
• The louver does not swing when the Indoor Fan Motor<br />
stops during operation at the upper limit.<br />
• When stopped with remote control, the discharge vent is<br />
reset, and stopped at the closing position.<br />
• During Anti-dew condensation prevention, Airflow Direction<br />
Auto-control angle change from 0° - 36° to 12° - 28° under<br />
Cooling and Soft Dry operation mode.<br />
1. There is no swinging while indoor fan motor is stopped during Cooling, Ion and Soft Dry operation.<br />
2. In Heating operation, when the piping air temperature reaches 38°C, the louver is changed from upper to lower limit position. When the<br />
piping air temperature falls to 35°C, the louver is changed from lower to upper limit position.<br />
Vertical Airflow Direction manual Control<br />
• When the manual Airflow Direction Selection Button is<br />
pressed, the automatic airflow is released and the airflow<br />
direction louver move up and down in the range shown in<br />
the diagram.<br />
The louver can be adjusted by pressing the button to the<br />
desired louver position.<br />
• When the remote control is used to stop the operation, the<br />
discharge vent is reset, and stopped at the closing position.<br />
• During Anti-dew condensation prevention, Airflow Direction<br />
Manual control angle change from 14°, 19°, 24°, 30°, 36° to<br />
16°, 18°, 20°, 22°, 24° under Cooling and Soft Dry operation<br />
mode.<br />