<strong>CS</strong>-<strong>W18CKE</strong> <strong>CU</strong>-<strong>W18CKE</strong> / <strong>CS</strong>-<strong>W24CKE</strong> <strong>CU</strong>-<strong>W24CKE</strong><br />

1. This equipment must be earthed. It may cause electrical shock if grounding is not perfect.<br />

2. Do not install the unit at place where leakage of flammable gas may occur. In case gas leaks and accumulates at<br />

surrounding of the unit, it may cause fire.<br />

3. Carry out drainage piping as mentioned in installation instructions. If drainage is not perfect, water may enter the room and damage the<br />

furniture.<br />

1. Selection of the installation location.<br />

Select an installation location which is rigid and strong enough to support or hold the unit, and select a location for easy maintenance.<br />

2. Power supply connection to the room air conditioner.<br />

Connect the power supply cord of the room air conditioner to the mains using one of the following method.<br />

Power supply point shall be the place where there is ease for access for the power disconnection in case of emergency.<br />

In some countries, permanent connection of this room air conditioner to the power supply is prohibited.<br />

1. Power supply connection to the receptacle using a power plug.<br />

Use an approved 16A power plug with earth pin for 2.0HP (V18CK, W18CK) and 20A for 2.5HP (V24CK, W24CK) for the connection<br />

to the receptacle.<br />

2. Power supply connection to a circuit breaker for the permanent connection. Use an approved 16A circuit breaker 2.0HP (V18CK,<br />

W18CK) and 20A for 2.5HP (V24CK, W24CK) for the permanent connection. It must be a double pole switch with a minimum 3 mm<br />

contact gap.<br />

3. Do not release refrigerant.<br />

Do not release refrigerant during piping work for installation, reinstallation and during repairing a refrigeration parts. Take care of the<br />

liquid refrigerant, it may cause frostbite.<br />

4. Installation work.<br />

It may need two people to carry out the installation work.<br />

5. Do not install this appliance in a laundry room or other location where water may drip from the ceiling, etc.<br />