INDUSTRIAL BUILDINGS'<br />

STANDARD M ETHODS OF MEASUREMENT<br />

METHOD B _ SCENARIO I: ONE STORY. SINGLE OCCUPANT<br />

Determining Rentable Area in an lndustrial Buildinq<br />

Using the Drip Line Methodology<br />

One Story, Single Occupant<br />

Refer to lllustration B1 and follow these five steps to<br />

determine the rentable area of the building;<br />

1, Determine the drip line area of the full floor bounded by<br />

the drio line. Refer to lllustration 2 and lllustration B'1,<br />

2. Determine the floor area of any permanent mezzanines<br />

or unclassified mezzanines bounded by the drip line<br />

at the building perimeter. Refer to lllustrations 3 and<br />

lllustration 81.<br />

3. Determine the total drip line area of the building by<br />

adding the full floor drip line area from step #1 io<br />

the mezzanine area from step #2. This will be the<br />

drip line area and rentable area of the building.<br />

4. ldentify all space located on either the full floor or a<br />

mezzanine that is finished and measure its floor area<br />

to the centerline of walls between it and adjacent<br />

unfinished areas.<br />

5. ldentify and measure any areas requiring disclosure,<br />

including<br />

. Restricted headroom area<br />

. Unclassified mezzanines<br />

. Connectors or portions thereof<br />

A tabulation of the results of applying these steps to the<br />

building shown in lllustration B1 is as follows<br />

Mezzanine<br />

Attached<br />

Mezzanine<br />

Stand-alone<br />

Ground Level<br />

Full Floor<br />

Totals<br />

FINISHED<br />

UN.FINISHED TOTAL<br />

4,294 2,227 6,521<br />

0<br />

1,936 1,936<br />

5,868 óJ,/C4 39,622<br />

.1<br />

0,1 62 37,917 48,079<br />

These areas reoresent the drio line area and the rentable area<br />

of the both building and the occupant.<br />

t 141<br />

TO AVOID I/ISINTERPRETATION, THIS PAGË SHOULD NOT BË USED WITHOUT THE COIiIPLETE DOCUIVlENT<br />