sample was LaNi 5 . This may indicate that the LaNi 5 was not in its normal crystalline<br />
form and the energy from the X-ray beam was inducing changes in the crystal phase.<br />
e<br />
Intensity (arb. units)<br />
d<br />
c<br />
b<br />
(111)<br />
a<br />
(101)<br />
(110)<br />
(200)<br />
(002)<br />
(112)<br />
(211)<br />
(202)<br />
(300)<br />
(301)<br />
(220)<br />
20 30 40 50 60 70 80<br />
2-Theta (deg.)<br />
a<br />
b, c, d, e<br />
LaNi 5 (reference)<br />
non-milled sample<br />
Figure 37. XRD spectra of LaNi 5 .<br />
LaNi 5 was ground with mortar and pestle in the glove box. The three consecutive<br />
scans in the XRD (Figure 38) resulted in spectra that involved peaks that matched with<br />
the reported peak positions of LaNi 5 . However, the relative intensity of the observed<br />
peaks did not match with the reported ratios, and, inconsistencies within the spectra were<br />
observed.<br />
77