Chapter 3 Functions and Operations<br />
Choosing FREQ/DIST in Spectrum Analyzer mode causes the soft keys, below, to be displayed<br />
and the corresponding values to be shown in the message area.<br />
� CENTER � Sets the center frequency of the Spectrum Analyzer display . Enter<br />
a value using the Up/Down arrow key or keypad, press ENTER to accept,<br />
ESCAPE to restore previous value.<br />
� SPAN � Sets the user-defined frequency span. Use the Up/Down arrow key<br />
or keypad to enter a value in MHz. Also brings up FULL and ZERO softkeys.<br />
� FULL span sets the Spectrum Analyzer to its maximum frequency span.<br />
� ZERO span sets the span to 0 Hz. This displays the input signal in an amplitude<br />
versus time mode, which is useful for viewing modulation.<br />
� START � Sets the Spectrum Analyzer in the START-STOP mode. Enter a<br />
start frequency value (in MHz) using the Up/Down arrow key or keypad,<br />
press ENTER to accept, ESCAPE to restore.<br />
� STOP � Sets the Spectrum Analyzer in the START-STOP mode. Enter a<br />
stop frequency value (in MHz) using the Up/Down arrow key or keypad,<br />
press ENTER to accept, ESCAPE to restore.<br />
3-13