SWEEP Displays the Sweep function soft key menu for the current operating mode.<br />

Sweep Menu Provides for changing the display resolution, single or continuous sweep, and<br />

access to the Trace Math functions.<br />

Choosing SWEEP in FREQ or DTF measurement modes causes the soft keys<br />

below to be displayed.<br />

� RESOLUTION — Opens the display to change the resolution. Choose 130,<br />

259, or 517 data points. (Not active in DTF mode. In DTF mode, resolution<br />

can be adjusted through the DTF-AID table.)<br />

� SINGLE SWEEP — Toggles the sweep between single sweep and continuous<br />

sweep. In single sweep mode, each sweep must be activated by the<br />

RUN/HOLD button.<br />

� TRACE MATH — Opens up the Trace Math functions (trace-memory or<br />

trace+memory) for comparison of the real time trace in the display with any<br />

of the traces from memory. (Not available in DTF mode.)<br />

Choosing SWEEP in SPECTRUM ANALYZER mode causes the soft keys below<br />

to be displayed.<br />

� RBW � Activates the resolution bandwidth functions. They let users manually<br />

adjust the resolution’s bandwidth to the desired value by scrolling using<br />

the Up/Down arrow key. Select desired value and press ENTER when complete.<br />

� VBW � Activates the video bandwidth function. It lets users manually adjust<br />

the resolution’s bandwidth to the desired value by scrolling using the<br />

Up/Down arrow key. Select desired value and press ENTER when complete.<br />

� MAX HOLD � Activates the max hold function. It displays and holds the<br />

maximum response of the input signal trace.<br />

� CONT/SINGLE � Toggles between continuous and single sweep.<br />

� OCC BW � Activates the second level occupied bandwidth menu.<br />

� OCC BW (second level)<br />

� METHOD � Selects the method to be used, dB Down or % of Power.<br />

� % � Enter the desired % of occupied bandwidth to be measured.<br />

� dBc � Enter the desired power level (dBc) to be measured.<br />

� MEASURE � Takes a measurement.<br />

� BACK � Returns to the top-level OCC BW menu.<br />