<strong>400</strong> <strong>Hz</strong>-Kabel für bewegliche Anwendungen<br />

<strong>400</strong> <strong>Hz</strong> <strong>Cables</strong> for mobile applications<br />

BETAjet® <strong>400</strong> FRNC-smartflex-V<br />

Flexible Andienkabel mit Steueradern<br />

BETAjet® <strong>400</strong> FRNC-smartflex-V<br />

Flexible power cables with control cores<br />

Anwendung<br />

Für flexible oder feste Anwendungen bei ausserordent lichen Klima verhältnissen und<br />

hohen mechanischen Beanspruchungen. In Hangars, Fluggast brücken, Kabeltrommelvorrichtungen<br />

usw. Für zivile und militärische Anwendungen.<br />

Aufbau<br />

� Leistungsadern: Kupferlitze blank, feindrähtig, VDE 0295, IEC 60228, Klasse 6<br />

Aderisolation: Ethylen-Propylen-Rubber (EPR) vernetzt<br />

Farben: Schwarz mit weissem Ziffernaufdruck 1 - 3, Neutralleiter blau<br />

� Steueradern: Kupferlitze verzinnt, feindrähtig, VDE 0295, IEC 60228, Klasse 5<br />

Aderisolation: Polyolefin Copolymer<br />

Farben: Weiss mit schwarzem Ziffernaufdruck, Nr. 1-18 … 24<br />

� Aussenmantel: Verschleissfestes Polyurethan (PUR) mit Kunstfaserverstärkung<br />

� Mantelfarbe: Gelb<br />

� Abriebanzeige: Orange<br />

Technische Daten<br />

� Nennspannung: U₀/U 115 / 200 V<br />

� Betriebsspannung: U₀/U max. 600 / 1000 V<br />

� Prüfspannung: <strong>400</strong>0 VAC, 50 <strong>Hz</strong><br />

� Betriebstemperatur: – 40 °C bis + 90 °C<br />

Normen / Materialeigenschaften<br />

� Halogenfrei: IEC 60754-1, EN 50267-2-1 (< 5 mg/g)<br />

� Keine korrosiven Gase: IEC 60754-2, EN 50267-2-2 (pH < 5)<br />

� Geringe toxische Gase: NES 02-713, NFC 20-454<br />

� Ölbeständigkeit: EN 60811-2-1 (24 h /100 °C)<br />

� Gute Abriebfestigkeit<br />

� UV-Beständigkeit<br />

� Flammwidrig: IEC 60332-1, EN 50265<br />

Application<br />

For flexible or static applications under extreme environmental conditions and high<br />

mechanical stress. In aircraft hangars, passenger bridges, cable retrievers etc. For civil<br />

and military applications.<br />

Construction<br />

� <strong>Power</strong> conductors: Bare fine copper strands, VDE 0295, IEC 60228, class 6<br />

Insulation: Cross-linked Ethylene-Propylene-Rubber (EPR)<br />

Colour: Black with numbers printed in white 1 - 3, neutral blue<br />

� Control cores: Tinned fine copper strands, VDE 0295, IEC 60228, class 5<br />

Insulation: Polyolefin copolymer<br />

Colour: White with numbers printed in black, No 1-18 … 24<br />

� Outer sheath: Abrasion resistant polyurethan (PUR) reinforced with fibres<br />

� Sheath colour: Yellow<br />

� Abrasion warning: Orange<br />

Technical data<br />

� Nominal voltage: U₀/U 115 / 200 V<br />

� Rated voltage: U₀/U max. 600 / 1000 V<br />

� Test voltage: <strong>400</strong>0 VAC, 50 <strong>Hz</strong><br />

� Operation temperature: – 40 °C to + 90 °C<br />

Standards / Material properties<br />

� Halogen free: IEC 60754-1, EN 50267-2-1 (< 5 mg/g)<br />

� No corrosive gases: IEC 60754-2, EN 50267-2-2 (pH < 5)<br />

� Low toxic gases: NES 02-713, NFC 20-454<br />

� Resistance to oil: EN 60811-2-1 (24 h /100 °C)<br />

� Good resistance to abrasion<br />

� UV resistance<br />

� Flame retardant: IEC 60332-1, EN 50265<br />

Neutral conductor<br />

reinforced<br />

<strong>Power</strong> conductor<br />

Insulation<br />

Control cores<br />

Tape<br />

Reinforcing/ orange abrasion<br />

indicator<br />

Outer sheath<br />

20 www.leoni-airport.com September 2009<br />

3<br />

2<br />

1<br />

1 2<br />

3