400 Hz Ground Power Cables 5 kV Airfield Lighting Cables - Leoni
400 Hz Ground Power Cables 5 kV Airfield Lighting Cables - Leoni
400 Hz Ground Power Cables 5 kV Airfield Lighting Cables - Leoni
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>400</strong> <strong>Hz</strong>-Kabel für bewegliche Anwendungen<br />
<strong>400</strong> <strong>Hz</strong> <strong>Cables</strong> for mobile applications<br />
BETAjet® <strong>400</strong> FRNC-smartflex-V<br />
Flexible Andienkabel mit Steueradern<br />
BETAjet® <strong>400</strong> FRNC-smartflex-V<br />
Flexible power cables with control cores<br />
Anwendung<br />
Für flexible oder feste Anwendungen bei ausserordent lichen Klima verhältnissen und<br />
hohen mechanischen Beanspruchungen. In Hangars, Fluggast brücken, Kabeltrommelvorrichtungen<br />
usw. Für zivile und militärische Anwendungen.<br />
Aufbau<br />
� Leistungsadern: Kupferlitze blank, feindrähtig, VDE 0295, IEC 60228, Klasse 6<br />
Aderisolation: Ethylen-Propylen-Rubber (EPR) vernetzt<br />
Farben: Schwarz mit weissem Ziffernaufdruck 1 - 3, Neutralleiter blau<br />
� Steueradern: Kupferlitze verzinnt, feindrähtig, VDE 0295, IEC 60228, Klasse 5<br />
Aderisolation: Polyolefin Copolymer<br />
Farben: Weiss mit schwarzem Ziffernaufdruck, Nr. 1-18 … 24<br />
� Aussenmantel: Verschleissfestes Polyurethan (PUR) mit Kunstfaserverstärkung<br />
� Mantelfarbe: Gelb<br />
� Abriebanzeige: Orange<br />
Technische Daten<br />
� Nennspannung: U₀/U 115 / 200 V<br />
� Betriebsspannung: U₀/U max. 600 / 1000 V<br />
� Prüfspannung: <strong>400</strong>0 VAC, 50 <strong>Hz</strong><br />
� Betriebstemperatur: – 40 °C bis + 90 °C<br />
Normen / Materialeigenschaften<br />
� Halogenfrei: IEC 60754-1, EN 50267-2-1 (< 5 mg/g)<br />
� Keine korrosiven Gase: IEC 60754-2, EN 50267-2-2 (pH < 5)<br />
� Geringe toxische Gase: NES 02-713, NFC 20-454<br />
� Ölbeständigkeit: EN 60811-2-1 (24 h /100 °C)<br />
� Gute Abriebfestigkeit<br />
� UV-Beständigkeit<br />
� Flammwidrig: IEC 60332-1, EN 50265<br />
Application<br />
For flexible or static applications under extreme environmental conditions and high<br />
mechanical stress. In aircraft hangars, passenger bridges, cable retrievers etc. For civil<br />
and military applications.<br />
Construction<br />
� <strong>Power</strong> conductors: Bare fine copper strands, VDE 0295, IEC 60228, class 6<br />
Insulation: Cross-linked Ethylene-Propylene-Rubber (EPR)<br />
Colour: Black with numbers printed in white 1 - 3, neutral blue<br />
� Control cores: Tinned fine copper strands, VDE 0295, IEC 60228, class 5<br />
Insulation: Polyolefin copolymer<br />
Colour: White with numbers printed in black, No 1-18 … 24<br />
� Outer sheath: Abrasion resistant polyurethan (PUR) reinforced with fibres<br />
� Sheath colour: Yellow<br />
� Abrasion warning: Orange<br />
Technical data<br />
� Nominal voltage: U₀/U 115 / 200 V<br />
� Rated voltage: U₀/U max. 600 / 1000 V<br />
� Test voltage: <strong>400</strong>0 VAC, 50 <strong>Hz</strong><br />
� Operation temperature: – 40 °C to + 90 °C<br />
Standards / Material properties<br />
� Halogen free: IEC 60754-1, EN 50267-2-1 (< 5 mg/g)<br />
� No corrosive gases: IEC 60754-2, EN 50267-2-2 (pH < 5)<br />
� Low toxic gases: NES 02-713, NFC 20-454<br />
� Resistance to oil: EN 60811-2-1 (24 h /100 °C)<br />
� Good resistance to abrasion<br />
� UV resistance<br />
� Flame retardant: IEC 60332-1, EN 50265<br />
Neutral conductor<br />
reinforced<br />
<strong>Power</strong> conductor<br />
Insulation<br />
Control cores<br />
Tape<br />
Reinforcing/ orange abrasion<br />
indicator<br />
Outer sheath<br />
20 www.leoni-airport.com September 2009<br />
3<br />
2<br />
1<br />
1 2<br />
3