Kabelsysteme zur Versorgung von Flugzeugen<br />
Technische Informationen<br />
Innentemperatur<br />
gemessen an Leiterisolation<br />
Temperatur °C / Temperature °C<br />
100<br />
90<br />
80<br />
70<br />
60<br />
50<br />
40<br />
30<br />
20<br />
0<br />
50 <strong>kV</strong>A 60 <strong>kV</strong>A 70 <strong>kV</strong>A 80 <strong>kV</strong>A 90 <strong>kV</strong>A<br />
Zeit Minuten / Time minutes<br />
BETAjet® <strong>400</strong> FRNC-deltaflex<br />
3 × (1 × 50 / 20 + 8 ×1) mm²<br />
BETAjet® <strong>400</strong> FRNC-smartflex-V<br />
1 × 35 + 6 × 35 + 6 × (4 ×1) mm²<br />
BETAjet® <strong>400</strong> FRNC-deltaflex<br />
3 × (1 × 70 / 25 + 8 ×1) mm²<br />
Umgebungstemperatur<br />
Ambient temperature<br />
<strong>Ground</strong> power cable systems<br />
Technical information<br />
Inner temperature<br />
measured on isolation of power conductor<br />
Obige Tabelle zeigt den thermischen Vorteil, den verdrillte Kabel aufweisen. Bei<br />
gleichem Querschnitt und gleicher Last werden verdrillte Kabel weniger warm als<br />
die Kabel mit runder Oberfläche (Aussenmantel). Grund ist die bei verdrillten<br />
Kabeln grössere Oberfläche, über welche die Wärme abgestrahlt werden kann.<br />
In the table, it can be seen, that for identical copper size and same load, the twisted<br />
cables have a lower core temperature than the single jacket composite cables. The<br />
reason is the bigger surface for heat dissipation.<br />
38 www.leoni-airport.com September 2009<br />
420<br />
� T = 65 °C<br />
� T = 50 °C<br />
� T = 36 °C