<strong>400</strong> <strong>Hz</strong>-Kabel für bewegliche Anwendungen<br />

BETAjet® <strong>400</strong> groundflex<br />

Vorteile<br />

� Orange Abriebanzeige<br />

� Gute Abriebfestigkeit<br />

� Hohe Flexibilität<br />

Abmessungen, Gewichte<br />

Dimensions, Weights<br />

Kabelaufbau<br />

Construction<br />

Artikel-Nr.<br />

Part no.<br />

Aussen-�<br />

Outer �<br />

Advantages<br />

� Orange abrasion indicator<br />

� Good resistance to abrasion<br />

� High flexibility<br />

Gewicht<br />

Weight<br />

Biegeradius fest verlegt<br />

Bending radius<br />

static installation<br />

Biegeradius bewegt<br />

Bending radius mobile<br />

n × mm² mm kg / km mm mm<br />

1 × 16 223916 10,7 216 > 64 > 96<br />

Elektrische Daten<br />

Electrical specifications<br />

Kabelaufbau<br />

Construction<br />

Artikel-Nr.<br />

Part no.<br />

Leitungswiderstand<br />

einadrig 1<br />

Conductor resistance<br />

single core 1<br />

Max. Kurzschlussstrom 2<br />

Max. short circuit 2<br />

n × mm² Ω / km A<br />

1 × 16 223916 1,316 1600<br />

1 bei 70 °C / typischer Wert<br />

2 bei 160 °C, nach IEC 60949<br />

September 2009 www.leoni-airport.com<br />

<strong>400</strong> <strong>Hz</strong> <strong>Cables</strong> for mobile applications<br />

BETAjet® <strong>400</strong> groundflex<br />

1 at 70 °C / typical value<br />

2 at 160 °C, according to IEC 60949<br />