400 Hz Ground Power Cables 5 kV Airfield Lighting Cables - Leoni
400 Hz Ground Power Cables 5 kV Airfield Lighting Cables - Leoni
400 Hz Ground Power Cables 5 kV Airfield Lighting Cables - Leoni
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>400</strong> <strong>Hz</strong>-Kabel für bewegliche Anwendungen<br />
BETAjet® <strong>400</strong> groundflex<br />
Vorteile<br />
� Orange Abriebanzeige<br />
� Gute Abriebfestigkeit<br />
� Hohe Flexibilität<br />
Abmessungen, Gewichte<br />
Dimensions, Weights<br />
Kabelaufbau<br />
Construction<br />
Artikel-Nr.<br />
Part no.<br />
Aussen-�<br />
Outer �<br />
Advantages<br />
� Orange abrasion indicator<br />
� Good resistance to abrasion<br />
� High flexibility<br />
Gewicht<br />
Weight<br />
Biegeradius fest verlegt<br />
Bending radius<br />
static installation<br />
Biegeradius bewegt<br />
Bending radius mobile<br />
n × mm² mm kg / km mm mm<br />
1 × 16 223916 10,7 216 > 64 > 96<br />
Elektrische Daten<br />
Electrical specifications<br />
Kabelaufbau<br />
Construction<br />
Artikel-Nr.<br />
Part no.<br />
Leitungswiderstand<br />
einadrig 1<br />
Conductor resistance<br />
single core 1<br />
Max. Kurzschlussstrom 2<br />
Max. short circuit 2<br />
n × mm² Ω / km A<br />
1 × 16 223916 1,316 1600<br />
1 bei 70 °C / typischer Wert<br />
2 bei 160 °C, nach IEC 60949<br />
September 2009 www.leoni-airport.com<br />
<strong>400</strong> <strong>Hz</strong> <strong>Cables</strong> for mobile applications<br />
BETAjet® <strong>400</strong> groundflex<br />
1 at 70 °C / typical value<br />
2 at 160 °C, according to IEC 60949<br />
25