Sodium Cycle <strong>Ion</strong> <strong>Exchange</strong> Process (Water Softening)<br />

The resin bed height correction is given in Figure 11. Leakage and capacity data presented here are<br />

based on resin bed depths of 30 inches (75 cm), the minimum depth recommended. Average leakage for<br />

the run is lower for deeper beds due to continually improving water during exhaustion. The capacity<br />

correction factors are shown for up to 10-ft (300-cm) beds. Modification of the vessel dimensions should<br />

be made by iteration using Figure 10 and Figure 11 until the final design is obtained.<br />

3.4.2 Counter-current Design<br />

Figure 11. Correction of operating capacity for resin bed depth.<br />

Leakage data presented in Figure 2 through Figure 4 are based on co-current operation. In designing<br />

counter-current softening systems, leakages are very low (expect