RMG 8 <strong>KNX</strong><br />

<strong>KNX</strong><br />

Switching actuators SYSTEMS<br />

Switch or blind actuators 4–16 channels<br />

RMG 8 <strong>KNX</strong> RME 8 <strong>KNX</strong><br />

Description<br />

Common functions<br />

■ 4- way blind or 8-way switching actuator<br />

■ Flexible channel function selection: As switching<br />

actuator or for controlling drives for<br />

blinds, shutters, sun and vision protection<br />

devices, skylights and ventilation fl aps<br />

■ Manual operation on device<br />

■ LED switching status display on device<br />

14<br />

■ Manual switch for Up / Down or for Switching<br />

On / Off (also without bus voltage)<br />

■ Optimised repetition accuracy of programmed<br />

lamella positions<br />

■ Slip correction when moving from bottom<br />

to top<br />

■ No referencing required<br />

Product selection Technical data<br />

Type Article number<br />

RMG 8 <strong>KNX</strong> 4900251<br />

RME 8 <strong>KNX</strong> 4900252<br />

Connection examples<br />

RMG 8 <strong>KNX</strong><br />

2<br />

C1.1<br />

C3.1<br />

3<br />

C1.2<br />

C3.2<br />

10 11<br />

6<br />

C2.1<br />

C4.1<br />

7 L N<br />

C2.2<br />

C4.2<br />

14 15<br />

<strong>KNX</strong><br />

N LL<br />

httpAdditional technical data at:<br />

www.theben.de/product/ Article number<br />

RMG 8 <strong>KNX</strong><br />

■ Basic module<br />

■ Can be upgraded to maximum of 8 blind or<br />

16 switching outputs<br />

RME 8 <strong>KNX</strong><br />

■ Extension module<br />

■ For upgrading to maximum of 8 blind or 16<br />

switching outputs<br />

RMG 8 <strong>KNX</strong> RME 8 <strong>KNX</strong><br />

Operating voltage <strong>KNX</strong> Bus voltage, (< 8 mA) –<br />

Operating voltage 230–240 V AC, 50 Hz<br />

Frequency 50 Hz<br />

Stand-by consumption 1,6 W 1,2 W<br />

Width 6 modules<br />

Type of contact<br />

NO contacts, 10 A (at 250 V AC, cos φ = 1),<br />

6 A (at 250 V AC, cos φ = 0.6)<br />

Ambient temperature –5 °C…+45 °C<br />

Protection rating IP 20<br />

Protection class II in accordance with EN 60 730-1<br />

RME 8 <strong>KNX</strong><br />

2<br />

C1.1<br />

C3.1<br />

3<br />

C1.2<br />

C3.2<br />

10 11<br />

6<br />

C2.1<br />

C4.1<br />

7 L N<br />

C2.2<br />

C4.2<br />

14 15<br />

N LL